Herunterladen Inhalt Inhalt Diese Seite drucken

DeFelsko PosiTector IRT Bedienungsanleitung Seite 8

Infrared thermometer
Vorschau ausblenden Andere Handbücher für PosiTector IRT:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Gage Info
Displays information on the gage body and attached probe.
Trend Chart
Turns the trend chart on. The trend chart can also be turned on by
pressing the Up navigation button from the main screen.
Emissivity
Sets the emissivity ratio for the PosiTector IRT infrared
temperature sensor.
Select Custom to manually adjust the emissivity value or to adjust
to a known temperature. Emissivity is automatically calculated
when adjusting to a temperature. See NOTE below.
Alternatively, use one of the following preset options:
Aluminum (rough) = 0.07
Zinc (Galvanized) = 0.25
Concrete = 0.54
Paint = 0.96
Emissivity
Zinc Galv. 0.25
Steel Ox. 0.95
Al Rough 0.07
Concrete 0.54
Wood 0.95
Paint 0.96
Plastics 0.94
Custom
Exit
NOTE:
Depending on surface treatment, metals such as blasted steel can
have a broad range of emissivity values. Adjusting to a known
temperature (measured by a direct contact surface temperature
probe) on a representative sample will assist in obtaining an
accurate emissivity value.
Flip Lock
Select to disable the auto rotate display feature.
Plastics = 0.94
Steel (Oxidized) = 0.95
Wood = 0.95
6

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis