If several parameters are displayed, you can switch from parameter to parameter by pressing the jog-wheel.
The active parameter is marked with a hook.
Adjust the crossover frequency and the filter type via the jog-wheel.
Equalizer
There are five parametric equalizers per output.
The individual equalizer band can be deactivated by pressing the Enter-button (Bypass). The symbol in the
upper right corner of the display changes to =.
Now you can adjust the frequency (20 Hz to 20 kHz), the Q-factor (0.5 to 10) and the gain (± 12 dB, ± 1 dB).
By pressing the jog-wheel, you can jump to the next parameter.
Additionally, you can switch the equalizers to shelving characteristic.
For doing so, set the gain to 0 dB. If you select a Q-factor below 0, you can choose between Hishelf and
Loshelf.
Limiter
The DXO-26/DXO-24 features a limiter-function with independent limiters (one per output).
The limiter serves as an additional clipping protection to avoid speaker damage. The signal level is always
limited to the adjusted threshold-level.
In most cases, it is sufficient to adjust the threshold-value to the clipping level of the connected amplifier.
Nevertheless make sure that the amplifier does not distort.
Via the jog-wheel, you can adjust the limiter between -20 and + 15 dB.
If the limiter will be adjusted to e.g. +2,0 dB the output signal level Limit corresponds to +2 dB and the levels-
2, -6, -12 and -20 dB correspond -1, -4, -8 und -12 dB.
Attack
You can adjust the Attack-time between 1 and 100 ms.
Hold
You can adjust the Hold-time between 0 and 100 ms.
Decay
You can adjust the Decay-time between 10 and 1000 ms.
Name
Via the jog-wheel, you can select the best fitting name from a preset name list.
Source
Via the jog-wheel, you can check the input sources Input A, Input B or Input A+B but not change it.

CLEANING AND MAINTENANCE

DANGER TO LIFE!

Disconnect from mains before starting maintenance operation!
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use