Herunterladen Inhalt Inhalt Diese Seite drucken

Environment Conditions - Barco e2 Sicherheitshandbuch

Vorschau ausblenden Andere Handbücher für e2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
1. Safety
1.3
Environmental Condition Check
Environment condition check
A device must always be mounted in a manner which ensures both air inlets and outlets are free. For installations in environments
where the device is subject to excessive dust, then it is highly advisable and desirable to have this dust removed prior to it reaching
the device clean air supply. Devices or structures to extract or shield excessive dust well away from the device are a prerequisite; if
this is not a feasible solution then measures to relocate the device to a clean air environment should be considered.
It is the customer's responsibility to ensure at all times that the device is protected from the harmful effects of hostile airborne particles
in the environment of the device. The manufacturer reserves the right to refuse repair if a device has been subject to negligence,
abandon or improper use.

Environment conditions

Table below summarizes the physical environment in which the E2 may be safely operated or stored.
Environment
Ambient Temperature
Air cleanliness
Humidity
Altitude
Environment
Do not install the device in a site near heat sources such as radiators or air ducts, or in a place subject to direct sunlight, excessive
dust or humidity. Be aware that room heat rises to the ceiling; check that temperature near the installation site is not excessive.
4
Operating
0°C (32°F) to 40°C (104°F)
Clean office environment (equivalent with cleanroom
standard ISO 14644-1 ISO Class 9)
5% to 85% RH Non-condensed
-60 (-197Ft) to 3000m (9843Ft)
Non-Operating
-10°C (14°F) to 60°C (140°F)
n.a.
0% to 95% RH Non-Condensed
-60 (-197Ft) to 10000m (32810Ft)
R5905947 E2 31/10/2014