This device should be used by trained chef or experienced person.
Any refitting is forbidden. It may cause serious accidents.
Burning without water on the heating tube is prohibited!
Shut off the power supply before cleaning.
Do not use water jet to clean this device or electric elements. It may cause leakage and shock accidents.
High temperature may cause scalding. Do not touch the device directly, especially the high temperature area.
Using the power supply if it's not matching the designed voltage is forbidden.
Do not use the switch which is not conform to the safety regulation.
When the thunder is getting close, the user should stop using and shut off the power supply to avoid damage.
Do not use hard or sharp object which may damage the surface of the device and heating tube.
Installation and maintenance must be performed by qualified professionals.
Keep your hands, the plug and switch dry during the installation.
If the power cable is damaged, please contact the manufacturer or service agent. And the replacement must
be performed by professionals to avoid danger.

5. Troubleshooting

Problem
1. Power on, the indicator is not
on and the heating tube is not
working.
2. Heating indicator on but the
temperature is not rising.
3. Temperature control is
normal, the indicator is not on.
4. Temperature rising is out of
control.
Problems above are only for reference. If there is any trouble, the user should stop using immediately and inform
professional to check and maintain.

6. Cleaning and maintenance

6.1
Shut off the power supply before cleaning for safety.
6.2
After use every day, the user can clean this device with a wet towel and non-corrosive detergent. Never
clean this device with a water jet to avoid water leakage and damage to the circuit.
6.3
When this device is not in use, the user should shut off the thermostat and power switch.
6.4
In case of long storage, this device should be cleaned completely and be put in well-ventilated and
non-corrosive warehouse.

Special Notes

Reasons
1. There is no power supply
1. Connecting wire of heating
tube is loose
2. Heating tube is burned
1. Indicator is burned
1. Thermostat is burned
www.combisteel.com
Solutions
1. Keep the electricity supply
connected
1. Fastening connecting wire
and screws of heating tube
2. Replace with new heating
tube
1. Replace by a new indicator
1. Replace by a new Thermostat