Maintenance

After every use, please clean with wet cloth, using washing tank if necessary. Oil receiver and rack can be taken
out to clean them drastically. It's strictly prohibited to clean the machine with water. If it's not used for a long
time, the stove should be cleaned and kept in a well-ventilated environment.

Notes

When barbecuing, keep the children and other people away to avoid scalding. If the stove is not used, the timer
and power should be shut down to prevent something bad from happening. All the service and maintenance
operations must be carried out after the power supply has been cut off. If there is a problem with the stove,
dismantle the machine "'and send it to our company's authorized service department or distributor for repair.

Warning

Prohibited to clean the machine with water! Water would lead to electric shocks and can hurt people.
When operating, hands must be dry! And hands must be kept away from timer and power etc.
High temperature can cause burns! Don't touch the heating pipe, toil and stove with your hand directly.
After it's finished, you should shut down the timer and the power!
If the power line was dilapidated or used too long time, it must be stopped! Change with the same
standard line or contact the supplier.
It should be put on the floor evenly to ensure safety, thanks for your cooperation.

Troubleshooting

NO.
Problem
Heating pipe works as normal,
1
but orange indication light out
of use.
Power on, but light indication
2
and heating pipe don't work as
normal.
Indication light works, but
3
heating pipes out of use.
These problems above are just for reference, if problems occur, stop the appliance, and return it to a
professional supplier for maintenance
Reason
Working indication light is
burnt out.
Timer burnt out.
1 Heating pipe was burnt out.
2 Inside lines not tight enough.
www.combisteel.com
Solution
Change working indication
light.
Change timer.
1 Change burnt heating pipe.
2 Check it, tighten up the
connection line.