Read these instructions before using the product. Save the instructions for future use.
GB
IMPORTANT! Before using the heater, the accompanying skids must be fitted to its sides. The fasting holes in the
skids are countersunk to accept the screw heads (see arrows, photo 1). Insert the screws several turns using the
Torx key included, but do not tighten them (see photo 2). Stand the heater on a flat surface, as in photo 3, and
tighten home all screws.
1
2
3
Use
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabili-
ties, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
This portable electric fan heater is intended for space heating. The heater is approved for use in humid conditions and rooms
where water may be present, and among its many uses it is suitable for building sites, storage spaces, shops or in the home.
It has been tested for electrical safety, and EMC tested by SEMKO. The fan heater is CE marked: Enclosure class: IP X4
(water splashing).
Safety
• Do not use this heater in or near a shower, bath or swimming pool.
• Stand the heater on a stable surface, so that it can not tip over.
• The heater must not be placed directly below an electrical outlet point.
• Place the heater well away from inflammable materials.
• The heater must not be covered, as this can cause overheating and risk of fire
(see photo A)
• Parts of the heater may become too hot to touch when it is in use.
A
Operation and controls for models DE 15 XS
The heater has a CEE-plug and must be connected to a 400V3N~
(see type designation plate).
The heater is switched on and off with the switch C (0-I).
Switch D is used to vary the heat effect, as follows:
DE 15 XS
– 7,5 kW
– 15 kW
C D
E
Thermostat 0-30 ºC
The thermostat (E) on DE 15 XS controls the temperature and connects the selected heating effect.
The fan can be set for continuous operation or thermostat controlled.
The heater is normally supplied with the fan set for continuous operation; i.e. the fan motor is in operation as long as the
heater is plugged in, irrespective of the thermostat setting. This will give the most even temperature distribution when heating
a space. The fan can be adjusted to be controlled by the thermostat; i.e. the thermostat will cut off the heater element and
fan simultaneously. The alteration must be done by an electrician; following the instructions found inside the cover.
Cleaning
Clean the heater at regular intervals, since dust and dirt may cause overheating and give rise to the risk of fire.
Service and repairs
The following work should be done by personnel from the manufacturer or a service company, or by equivalent qualified
personnel:
Changing the power supply cable.
The heater has a built-in temperature limiter that will trip the power supply in the event of overheating.
If the temperature limiter has tripped, isolate the power supply to the heater, allow the heater to cool down and attend to
the fault.