Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Revolution 975916 Gebrauchsanweisung

Sahnegerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8

4. TROUBLESHOOTING

The charger is not pierced open:
An unsuitable charger has been used or charger was inserted incor-
rectly. Use the exclusively disposable Revolution cream charger and
place it in the charger holder as shown in Fig. 1.
You have not pressed the lever, nevertheless, cream fl ows from the
nozzle and can't be stopped:
a) Additives such as powdered sugar, cream stiffener, pulp, etc. have
not been completely dissolved, blocking the piston. Turn the whip-
per into upright position (nozzle up), place it on the countertop and
wait until content has settled on the bottom. Cover the nozzle well
with a heavy towel and carefully press the lever to release gas until
hissing sound stops, then unscrew the head, clean the dispensing
piston, strain contents and refi ll the whipper.
b) The dispensing piston is damaged. Send the appliance to Hendi or
a service center.
When the charger is being screwed in, gas escapes between the
bottle and the head:
a) The head gasket is missing. Insert a head gasket in the head.
b) The head gasket is damaged. Insert a new gasket.
c) The head is not screwed on fi rmly enough. Screw the head onto
the bottle fi rmly in accordance with User Instructions.
d) The upper edge of the bottle is damaged. Send the appliance to
Hendi or a service center.
Cream is still liquid after preparation:
a) The whipper was not shaken fi rmly or often enough. Shake again
fi rmly.
b) The whipper was not turned upside down when pressing the lever.
Always turn the whipper upside down before pressing the lever
(decorating nozzle pointing vertically downward!)
EN
Cream is too firm and "spits" sideways from the nozzle:
The whipper has been shaken too much. Do not over shake nor
shake before each dispensing.
IMPORTANT: Do not attempt to modify the whipper. If you cannot
solve a problem with the help of these instructions, please contact
Hendi or a service center.
Cleaning
Before opening, allow remaining pressure to escape by pressing the
lever until no cream or gas is discharged through the nozzle. An in-
signifi cant amount of cream may remain in the bottle – a teaspoon of
liquid cream at the most.
Follow steps 1, 2 and 3 to clean your Revolution Cream Whipper:
1. Unscrew the head then remove the head gasket and decorating
nozzle. Hold end of the piston inside the head while unscrewing
the nozzle adaptor with the other hand.
2. Thoroughly clean each individual component with a mild detergent
and a brush.
6

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Revolution 975916

Inhaltsverzeichnis