(1)
12-15V AC
> 400mA
(1)
(1) Power Supply Socket
This is the socket to which the plug from the external power supply is connected (12-15V
AC, min. 400mA, more mA is no problem)
(2) Bus connectors
These are the pin headers which are used to connect the A-100 modules. Up to four
modules can be connected:
Please calculate the total current requirement of the modules that have to be
installed into the A-100MC (or driven by the A-100MNT/MBP).
Check that this total is less than 200 mA. Otherwise the A-100MNT/MBP is not
suitable.
Check if each module is equipped with a ribbon cable with a 16 pin female
connector at the open end. The ribbon cable can be 10 or 16 pin but the female
connector has to be 16 pin !
Now join the free end of the ribbon cable to the nearest available position on the bus
board
For this one has to plug the female 16 pin connector at the free end of the ribbon
cable to one of the pin headers of the bus (these are also 16 pins). Use a pin header
of the bus board that is close to the position where the module has to be mounted
later.
Check very carefully that it is connected so that the coloured marking on the ribbon
cable is at the bottom of the bus connector. The coloured marking has to align