Herunterladen Inhalt Inhalt Diese Seite drucken

Short Instructions - Benning PV 1-1 Kurzanleitung

Vorschau ausblenden Andere Handbücher für PV 1-1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Measured value memory (200 display screens)
-Store
+
Clear all results from memory.
Reading out the measured value memory via the USB interface
3.
5.
Preset limiting values
V
Limiting value of insulating resistance
ISO
Measuring range
Function
Setting the date and time
-key and then press simultaneously the
the
Auto
MM.DD = month (1-12). Day (1-31)
YYYY = year
-key to select a date field and time field
R
PE
6. With the
-key and the
-
each change, the second field is set to zero.
Note:
Setting the Auto Power Off (APO, Auto-Power Off)
-key and then press simultaneously the
NULL
the
-
-key pressed.
Auto
NULL
in minutes.
-key increases the shutdown time by one minute to 10
V
ISO
minutes.
BENNING PV 1-1
5. Then release the
-
Radio connection to BENNING SUN 2 - wireless SUN link
Coupling with insolation/temperature measuring instrument BENNING SUN 2
-key for approx. 2 seconds.
2
Decoupling from insolation/temperature measuring instrument BENNING SUN 2
10 seconds.
Range
means of an acoustic signal and by clearing the LC display.
Activating/deactivating the radio transmission of the BENNING SUN 2
-key and
R
PE
4.
2
Note:
Error codes
Error codes
-key and
R
PE
5
-
NULL
-key and the
-key of the
R
Auto
PE
-key and the
R
Auto
PE
2
) is shown on the LC display of the
Remedy
ting instructions for details.
reached the maximum admissible temperature. Disconnect the
cool down.
The measurement has been stopped.
BENNING PV 1-1

Short Instructions

-
BENNING PV 1-1
Important information
Before using the BENNING PV 1-1 please read the detailed operat-
ing manual (CD-ROM) carefully.
The BENNING PV 1-1 should only be used by suitably trained per-
sonnel.
The connection to the PV generator is made exclusively in accord-
ance with the connection figure of the operating manual.
Disconnect not required safety tests leads from the BENNING PV 1-1.
The PV module/PV string must not exceed the maximum open-
circuit voltage of 1000 V DC, the maximum short-circuit current of
15 A and the maximum DC power (P = U x I) of 10 kW.
According to DIN EN 62446, the measurements have to be made for
each PV string.
Measurements made at PV strings which are connected in parallel
might involve an overload of the BENNING PV 1-1.
Disconnect the BENNING PV 1-1 from the test sample directly after
the test.
Do not touch the measuring probes! During insulating resistance
-key of
measurements, high electric currents might be applied to the meas-
uring probes.
Do not touch any metal parts of the test object during measure-
ment.
The PV generator must be isolated from the electric power supply!
Neither the positive nor the negative pole of the PV generator must
be earthed!
Via the 4 mm safety test leads, voltage measurements on mains
supply circuits are possible. Via the 4 mm test sockets, the
BENNING PV 1-1 must be used only in electric circuits of overvolt-
age category III with max. 300 V AC/DC for phase-to-earth measure-
ments. For this please disconnect the PV 1-1 measuring leads from
the PV test sockets before measuring.
Before starting the unit, always check it for signs of damage. Do not
-
use a damaged BENNING PV 1-1!
Only use safety measuring leads, which are supplied with the
BENNING PV 1-1.
The BENNING PV 1-1 is intended for making measurements under
dry ambient conditions only.
Switching the device ON/OFF
-key and the
-
R
Auto
PE
minute (APO, Auto Power-Off).
6
BENNING PV 1-1
1

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis