RALLY MIG 161i - Factory setting
Setting possibilities
Area
Primary parameters:
1
Welding current
Area depends on
program
Wire feed speed
Thickness of material
2
Arc length
-9.9 – +9.9
Secondary parameters:
1
Hotstart (MMA/TIG)
0 - 100
3
Arc power (MMA/TIG)
0 - 150
TIG process (TIG)
ON/OFF
1
Arc Adjust (MIG)
-5.0 – +5.0
6
Burnback (MIG)
1 – 30
Programs
No:
Wire
Material
Gas
P501
Ø 0.8 mm
CuAl
Ar
P509
Ø 0.9 mm
CuAl
Ar
P502
Ø 1.0 mm
CuAl
Ar
P201
Ø 0.8 mm
CrNi
ArCO
P209
Ø 0.9 mm
CrNi
ArCO
P202
Ø 1.0 mm
CrNi
ArCO
P311
Ø 0.8 mm
Al AlMg5
Ar
P319
Ø 0.9 mm
Al AlMg5
Ar
P352
Ø 1.0 mm
Al AlSi5
Ar
Note: Fe programs with reversed polarity are recommended for
Innershield wires
Step
Factory setting
2T
1
Depending on
program
0.1
0.1
0.1
0.0
1
25
1
25
OFF
0.1
0.0
1
5
No:
Wire
Material
P106
Ø 0.6 mm
Fe
P101
Ø 0.8 mm
Fe
P109
Ø 0.9 mm
Fe
(98/2)
P102
Ø 1.0 mm
Fe
2
(98/2)
P116
Ø 0.6 mm
Fe
2
(98/2)
P111
Ø 0.8 mm
Fe
2
P119
Ø 0.9 mm
Fe
P112
Ø 1.0 mm
Fe
QUICKGUIDE RALLY MIG 161i
Unit
A
m/min
mm
V
%
%
-
ms
Gas
CO
2
CO
2
CO
2
CO
2
CO
Mix
2
CO
Mix
2
CO
Mix
2
CO
Mix
2