Operating temperature
Storage temperature
Relative air humidity, max.
Laser class
Laser type
C
(laser line)
6
C)D)
Laser line width
– at a distance of 5 m
– at a distance of 10 m
Tripod mount
Batteries
Operating time, approx.
Weight according to EPTA-Procedure
01/2003
Dimensions (length x width x height)
A) After calibration at 0 ° and 90 ° at an additional pitch error of max. ±0.02 °/degree
up to 90 °.
B) over 25 °C gradual deterioration
C) at 25 °C
D) The width of the laser line depends on the surface characteristics and on the ambi-
ent conditions.
The measuring tool can be clearly identified with the serial number 10 on the type
plate.
Assembly

Inserting/Replacing the Batteries

Alkali-manganese batteries are recommended for the measuring tool.
To open the battery lid 7, press on the latch 8 and fold the battery lid up.
Insert the batteries. When inserting, pay attention to the correct polarity
according to the representation on the inside of the battery lid.
Always replace all batteries at the same time. Only use batteries from one
brand and with the identical capacity.
1 609 92A 13M | (14.9.15)
PLL 2
+10 °C...+40 °C
–20 °C...+70 °C
90 %
2
640 nm, <1 mW
1
≤3 mm
≤6 mm
1/4"
3 x 1,5 V LR03 (AAA)
5 h
0.4 kg
123 x 67 x 110 mm
Bosch Power Tools

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pll 2