Operating instrutions
Error indication or
Error code in the display
of the pump
E20
E40
Please contact a specialist technician should it not be possible to eliminate the fault.

13 Disposal

Do not dispose of the pump and/or individual parts in household waste!
Dispose of the pump and/or parts in an environmentally conscious way.
To do this, please contact a public or private disposal organisation.
A list of the materials used in our products is provided in the download
area of our website. (www.wita.de)
36
WITA go.future LCD 40-XX | 60-XX
Causes
Rotor blocked
Overcurrent protection circuit
remedy
Switch the pump off and secure against being
switched back on.
If possible, close the shut-off valve in front of and
behind the pump or drain the water.
Depending on the operating condition of the system,
hot water can escape! Risk of burns!
Unscrew the 4 head cap screws and remove the
pump head by loosening the motor head.
Pump impeller must be able to rotate easily.
Remove any impurities or foreign bodies and reas-
semble the pump.
If the error persists, the pump must be replaced.
Press any key or disconnect the pump for minimum
1 minute from the power supply
Is the error still existing the pump must be replaced