Replacing A Lost Or Broken Control Point; Restoring The Original Confi Guration - SOMFY Solamagic Programmierhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
The
Heating
Mod/Var
Ramp RTS-HR1 does
not heat up suffi ciently.
(next)
The
Heating
Mod/Var
Ramp RTS-HR1 does
not switch on.

4.2 Replacing a lost or broken control point

Caution: This reset is carried out if all the RTS control points have been lost or
broken.
Caution! This reset removes all control points but retains the favourite heat
level programmed.
Caution! Only switch off the power to the Heating Mod/Var Ramp RTS-HR1 to
be reset!
CAUTION! Do not use an Inis RT/Inis RTS control point for resetting
1) Cut the power supply for 2 seconds.
2) Switch the power supply back on for approximately 10 seconds (for at least
5 seconds but no longer than 15 seconds).
3) Cut the power supply for 2 seconds.
4) Switch the power supply back on: the heating lamp fl ashes slowly.
5) Briefl y press the PROG button on the new RTS control point (f):
The heating lamp will come on then go out again to indicate that the new
RTS control point has been programmed into the Heating Mod/Var Ramp RTS-HR1.

4.3 Restoring the original confi guration

Caution! This reset removes all control points and resets the favourite heating
level to 33% of the total power.
Caution! Only switch off the power to the Heating Mod/Var Ramp RTS-HR1 to
be reset!
Caution! Do not use the Inis RT/Inis RTS control point for resetting!
1) Cut the power supply for 2 seconds.
2) Switch the power supply back on for approximately 10 seconds (for at least
5 seconds but no longer than 15 seconds).
3) Cut the power supply for 2 seconds.
4) Switch the power supply back on: the heating lamp fl ashes slowly.
5) Press the PROG button on the RTS control point until the heating lamp
comes on then goes out twice in succession: all control points have been
removed.
Follow the procedures in the section entitled "Commissioning" to add RTS
control points.
The capacity of the Heating Mod/Var
Ramp RTS-HR1 is not suffi cient.
The correct fuse has not been fitted to
the equipment.
One or more heating lamps is blown
or broken.
The heating lamp(s) linked to the
Heating Mod/Var Ramp RTS-HR1
exceed 2000 W.
See the heated surface in the technical
data.
Check the rating of the fuse. To operate
the ramp correctly, a 16 A delay fuse is
required.
Replace the heating lamp(s).
Ensure that the heating lamp(s) linked
to the Heating Mod/Var Ramp RTS-
HR1 do not exceed 2000 W in total.
12