Problem
‡ Motor does not run in
Automatic mode
‡ Acoustic warning
signal triggered
(reduced suction
power) SQ 890-3M/
B1: Display S2
‡ No suction power
during wet cleaning
SQ 890-3M/B1:
Display S1
‡ No acoustic warning
signal when volume
flow drops below
minimum
GUARANTEE
14
Cause
> Compressed air supply
below 4 bar
> Electrical tool faulty or
not correctly
connected
> Suction force regulator
set too low
> Hose diameter is not
compatible with
switch position
> Suction hose is
blocked
> Filter bag is full
> Filter element is soiled
> Ball valve at drainage
hose is open
(SQ 890-3M/B1 only)
> Tank full (float switch
closing off the suction
opening,
SQ 690-3M/B1
only)
> Faulty monitoring
electronics
Guarantee and warranty
are subject to our General
Conditions of Sale and
Delivery.
Subject to changes in the
course of technical
innovations.
Remedy
Increase operating
pressure, see section
'Technical Data'
Check electrical tool
for faults and push
plug in firmly
Adjust the knob in a
clockwise direction
Adjust switch position
to hose diameter
Clean the suction hose
See section 'Changing
the filter bag'
See section 'Replacing
the filter element'
Close the ball valve
Switch off cleaner.
Empty tank
Have repaired by WAP
Service Dept