The phase-sequence indicator TRITEST
measuring instrument for testing the phase sequence
Manual de instrucões
of three-phase mains (subdistributions, sockets etc.).
The applicable three-phase nominal voltage range
Instrukcja obsługi
is 400 V - 690 V, 50 Hz - 60 Hz. As supplementary
Instrucţiuni de utilizare
device, the measuring instrument is equipped with an
integrated battery-powered LED pocket lamp. Before
Инструкция по эксплуатации
using the measuring instrument, carefully read this
operating manual and always observe the safety
Bruksanvisning
instructions!
Dutest aletinin kullanma
List of contents
1.
Considerations for use
tarifnamesi
2.
Safety instructions
3.
Scope of delivery
Priručnik za upotrebu
4.
Functional description of the phase-sequence
indicator
5.
Battery installation/ battery indication
6.
How to test the phase sequence
7.
Pocket lamp function
8.
Technical data
9.
Maintenance
10. Environmental notice
1.
Considerations for use
This operating manual is addressed to
-
-
The TRITEST
dry ambient conditions and must not be used for three-
phase mains with a nominal voltage higher than 690 V
AC (also see section 9 „Technical data").
The following symbols are used in this operating
manual and on the TRITEST
symbol
2
L1
3
L2
L3
2.
Safety instructions
-
The device is designed and tested according to
DIN EN 61557-7/ VDE 0413-7, DIN EN 61557-1/
VDE 0413-1 and left our works in technically
safe condition. To preserve this condition and to
ensure safe operation, the user has to observe
all instructions and warnings contained in this
operating manual.
-
During testing, hold the device by the insulated
test handles A, B and C only and do not touch
the testing electrodes (probe tips)  !
-
Before opening the housing cover 4 (battery
compartment), separate the test handles A, B
and C from all voltage sources and measuring
circuits!
-
Remove the batteries, when you do not use the
device for a longer period of time!
-
Do not dispose of used batteries via the household
rubbish! Dispose of those batteries via special
waste facilities!
-
Please observe: Working on live parts and
systems is dangerous! Even voltages from 30 V
AC and 60 V DC onwards might involve life-
Operating manual
threatening dangers for people!
-
Check the device for damages before each
TRITEST
control
®
measurement.
-
Always protect the measuring instrument against
control is a
moisture or dampness. Furthermore, protect it
®
against contamination and damages!
-
Protect the device against condensation water.
Condensation water might form, if the device is
brought from a cold into a warm environment.
Thus, the insulating power inside the device might
be reduced and measuring and insulating faults
might occur. In such a case, store the device in an
appropriate environment at a higher temperature
for approx. 1 hour.
-
If it can be assumed that safe operation is no
longer possible, put the device out of operation
and secure it against unintended operation.
-
Safe operation is assumed to be no longer
possible, if
-
-
-
-
3.
Scope of delivery
The scope of delivery of the TRITEST
of:
professional electricians and
3.1 one TRITEST
electrotechnically trained people.
3.2 one safety probe tip L1, brown (tip Ø = 4 mm,
®
control is intended for being used in
3.3 one safety probe tip L2, black (tip Ø = 4 mm,
3.4 one safety probe tip L3, grey (tip Ø = 4 mm,
3.5 one safety alligator clip, black (jack Ø = 4mm,
control:
®
4.
Functional description of the phase-sequence
meaning
indicator
The phase-sequence indicator TRITEST
Warning of electric danger!
equipped with two integrated voltage divider systems
Indicates instructions that must be
with star connection. One of the systems indicates the
observed in order to prevent danger for
phase LED (indication of the phase voltages L1 9 , L2
people.
7 , L3 5 ). The other system (combined resistance and
Attention! Observe documentation!
capacitor) ensures the phase-sequence indication by
This symbol indicates that there are
means of two LEDs 8 and 6 . The capacitor (reactive
instructions in the operating manual that
impedance) and the resistances (active resistance)
must be observed to prevent dangers.
build up a phase shift and is almost in phase with a
rotary field (travelling wave). The respective LED
Continuous double or reinforced insula-
(clockwise 8 or anti-clockwise 6 phase sequence)
tion (protection class II)
gets the higher voltage and is activated.
Phase sequence clockwise
Note:
The phase sequence can be tested even with the
Phase sequence anti-clockwise
batteries being removed or empty.
Connecting marks on the connecting/
5.
Battery installation/ battery indication
test cables; phase LEDs signalling
Before opening the housing cover 4 , separate the
voltage at L1, L2, L3
test handles A, B and C from all voltage sources and
measuring circuits.
This symbol indicates the alignment
The battery compartment is behind the housing cover
of the batteries for being inserted with
4 at the back of the device. There are apertures on
correct polarity.
the sides of the device to release the cover. For this
purpose, use a 5.5 mm slotted screwdriver by means
Symbol for pocket lamp function
of which you can move the cover over the holding
notch with a rotary movement. Thus, the cover can be
removed.
Ground (voltage to ground)
Please ensure correct polarity when inserting the
batteries (see battery symbol)!
When closing the housing, make sure that the cover
locks into place correctly and that there is no gap on
the side of the housing.
In case of low battery voltage, the pocket lamp cannot
be operated. Please replace the batteries!
6.
How to test the phase sequence
Contact the connecting cables (test cables) L1, L2,
L3 with the mains to be tested. If necessary, use the
probe tips A, B and C and the alligator clip J .
The phase voltages are indicated by means of the
LEDs L1 9 , L2 7 und L3 5 .
Depending on the connection, the LED for "clockwise
phase sequence" 8 or for „anti-clockwise phase
sequence" 6 is activated. Please observe for each
testing that all of the three phase voltages have to be
present to obtain a correct indication!
7.
Pocket lamp function
The LED lamp 2 can be switched on via the sliding
switch 3 integrated into the side of the device. The
pocket lamp function can be operated independently
of the phase-sequence indicator system.
8.
Technical data
-
Regulations, phase-sequence indicator:
DIN EN 61557-7/ VDE 0413-7, DIN EN 61557-1/
VDE 0413-1, reference DIN EN 61010-1
-
Nominal voltage range: 3-phase AC current
400 V - 690 V
-
Max. voltage to ground: 400 V
-
Over voltage category: III (IEC/ EN 61010-031)
-
Testing current: ≤ 3,5 mA
-
Nominal frequency range: 50 Hz - 60 Hz
-
Curve behaviour of mains voltage: sinusoidal
-
EMC, resistance to interference:
DIN VDE 0843-20 IEC/ EN 61326
-
Working temperature range: - 10 °C to 50 °C
-
Storing temperature range: - 25 °C to 75 °C
-
Humidity: 80 % to 31 °C, linearly decreasing, 40 %
to 50 °C, not condensing!
-
Altitude above sea level: 2000 m
-
Protection class: 2 (IEC 60536)
the device exhibits visible damages (housing,
-
Protection type: IP 30 (DIN VDE 0470-1 IEC/
cable, test handles),
EN 60529)
the device no longer works,
3 - first index: Protection against access to
the
device
has
been
stored
under
dangerous parts and protection against solid
unfavourable conditions for a longer period of
impurities of a diameter > 2.5 mm
time,
0 - second index: No protection against water
the device was exposed to mechanical stress
-
Degree of contamination: II (IEC 60664)
due to transport.
-
Batteries: 3 round cell batteries 1.5 V (4.5 V, 70 g),
(IEC/ DIN R6/ LR6)
-
Lamp, LED, power consumption: 25 mA at 4.5 V
control consists
battery voltage
®
-
Illumination: approx. 30 lux in a distance of 50 cm
control with fixed connecting
-
Usable life of the battery: approx. 100 h with alkali-
®
cables, L1, L2, L3
manganese batteries
-
Dimensions: 97 x 59 x 30 mm (without testing
TN 709266)
cable)
-
Weight: approx. 320 g with measuring accessories
TN 709267)
and battery
-
Testing cable length: approx. 1000 mm
TN 709268)
9.
Maintenance
TN 709269)
For cleaning the device, use a cloth which is moistened
with a mild cleaning agent. If there is electrolyte
contamination or white deposit near the battery ort he
battery compartment, remove them with a dry cloth.
control is
Remove the batteries from the device when not using
®
it for a longer period of time!
If the LED lamp 2 does not work any longer or
becomes weak, replace the batteries by new ones of
the same type.
10. Environmental notice
At the end of the product's useful life, please
dispose of it at appropriate collection points
provided in your country.