moVement and installation
• When moving the unit, the angel between the cabinet and the ground should not be
less than 45o in order to protect the compressor and refrigerating system.
• Position the unit in a dry and well-ventilated place. Keep the freezer away from
direct sunlight, heaters and corrosive gases.
• The normal operation of the unit depends on the heat radiation of the condenser. For
the initial use, the packing foam must be taken off and at least 150mm space must be
left around the unit.
test-run
• At DC input condition, the voltage range required is DC10.9V~28V, if the power is
not stable, the unit will not run. The unit will restart when the voltage is normal. Cut
out 10.4VDC, cut in 11.8VDC.
• Do not pull the appliance by power cord.
• Connect power, set the digital thermostat to -18°C and check the indicators, 30 mi-
nutes later, open the door and check the inside surface. If the inside surface is cold,
your appliance is working.
Foods storing
• Fresh foods should not be stored together with frozen foods.
• When the temperature is set below 0°C (the unit is used as a freezer), do not store
any glass-bottled drinks such as beer and lemonade as the bottles might crack.
deFrosting and de-odoriZing
• When the ice layer on the inner cabinet sides is over 5mm, defrosting operation
should be performed to improve the refrigerating efficiency.
• Switch off power, remove all items and clean unit. After defrosting and all the water
has drained out, clean with a soft rag and switch the appliance on.
• Note: never remove ice with sharp objects.
• Place charcoal in the appliance to remove any bad odours.
Bedienungsanleitung_Kühlschrank_Multi.indd 12-13
maintenance and regular cleaning
• Always disconnect the power supply before cleaning. Clean the inside of the cabinet
whenever necessary using a warm solution of water and bicarbonate of soda
(1 tablespoon to every 2 liters of water) dry with a soft cloth
• Dirt from the condenser should be cleaned by a qualified technician when necessary.
not a malFunction
• It is normal to hear gurgling sounds caused by the flow of refrigerant when each
cooling cycle ends.
• The surface temperature of the compressor can reach 70-90°C when running.
• The noise emitted by the cooling fan on the condenser is a normal condition.
main technical parameter
Model:
Efficient volume:
Refrigerant:
Insulations:
Class:
Input power:
Input Voltage:
Current:
Temperature of freezing:
Temperature of refrigerating:
Dimension(LxDxHmm):
DC-60
60 L
R134A, 60Grams
Cyclopentane
N, SN
65W DC
DC12V/24V
5.42A / 2.71A
-15 °C
0 bis 10 °C
485 x 490 x 590 mm