Herunterladen Inhalt Inhalt Diese Seite drucken

Remote Control (Only Sps 1560 Pfc) - VOLTCRAFT SPS 1525 PFC Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für SPS 1525 PFC:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Proceed as follows for connection:
• Always connect the supply cables from the power unit to the consumer. Pay atten-
tion to correct polarity.
• Press the orange-coloured terminal on the SENSE connection inwards with a small
screwdriver and insert the cables into the green terminal openings. Check that
they are plugged firmly.
• Now connect the two "SENSE" cables to the consumer observing the correct
polarity. The conductor cross-section for the "SENSE" cables must be at least
22AWG (= 0,34mm2) .
• Always slacken the connection in the reverse order (first of all the "SENSE" cables
and then the connecting cables).
Make sure that you contact the SENSE cables as close as possible to
the connecting point of the consumer.
Never short the "SENSE" cables.

REMOTE control (only SPS 1560 PFC)

Through the built-in "REMOTE" control connection, the voltage setting can take pla-
ce with an external voltage source or through an externally adjustable resistance
(short "poti") and it´s possible to switch the DC output on/off.
The REMOTE connection takes place on the rear REMOTE built-in plug (14).
Preparation of the remote control connection.
Turn the central screw of the supplied slide-in jack and remove the front, black
contact jack by means of a small turning movement.
Draw the five connecting cables with a conductor cross-section of at least 22AWG
(=0,34mm2) through the metal sleeve from the rear. Solder these five cables firmly
and carefully to the soldering lugs no.1,2,3,7 and 8 of the black contact jacks.
24

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sps 1560 pfcSps 1540 pfc

Inhaltsverzeichnis