Model
Item no.: (PlugIn)
Item no.: (Schuko)
Input voltage [VDC]
Constant output power [W]
Peak power (10ms) [W]
Output volt tolerance [%]
Output voltage, pure sine wave [VAC]
Efficiency [%]
No load power [A]
Thermal protection, auto-shut off [ºC]
Cooling fan
Short circuit protection
Soft start
Over volt protection
Auto shut-off at [V]
Alarm for low voltage [V]
Auto shut-off at [V]
Protection against wrong polarity (Fuse)
Input fuse [A] (Number)
Operating temp [ºC]
Size [mm]
Weight (w/o cables) [Gram]
DEFA confirms that these inverters satisfy relevant safety requirements according to prevailing regulations and standards.
6
TECHNICAL DATA: 300W AND 600W MODELS
300W-12V
16,0 (± 1,0)
10,5 (± 0,5)
10,0 (± 0,5)
230x150x63
2000
702935
702936
10-16
300
750
± 5
230
> 85
< 0,7
60 (±10)
Yes
Yes
Yes
Yes
Yes
40
-20 to +60
2000
600W-12V
702937
702938
10-16
600
1200
< 0,6
16,0 (± 1,0)
10,5 (± 0,5)
10,0 (± 0,5)
32 (2)
324x170x68
3500
3500