Herunterladen Inhalt Inhalt Diese Seite drucken

Daikin ERLQ004CAV3 Referenzhandbuch Für Den Monteur Seite 98

Daikin altherma – geteiltes niedertemperaturgerät
Vorschau ausblenden Andere Handbücher für ERLQ004CAV3:
Inhaltsverzeichnis

Werbung

14 Technische Daten
Englisch
Indoor unit supplied from outdoor Innengerät durch Außengerät
Normal kWh rate power supply
Only for normal power supply
(standard)
Only for preferential kWh rate
power supply (outdoor)
Outdoor unit
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
Use normal kWh rate power
supply for indoor unit
(2) Backup heater power supply
Only for ***
(3) User interface
Only for remote user interface
option
Switch box
(4) Domestic hot water tanks
3 wire type SPST
Booster heater power supply
Only for ***
Only for wall-mounted models
Switch box
(5) Ext. thermistor
Switch box
(6) Field supplied options
12 V DC pulse detection (voltage
supplied by PCB)
230 V AC supplied by PCB
Continuous
DHW pump output
DHW pump
Electrical meters
For safety thermostat
Inrush
Max. load
Normally closed
Normally open
Referenzhandbuch für den Monteur
98
Übersetzung
gespeist
Normaltarif-Netzanschluss
Nur für normale
Stromversorgung (Standard)
Nur für Wärmepumpentarif-
Netzanschluss (außen)
Außengerät
Wärmepumpentarif-
Netzanschlusskontakt: 16 V DC-
Erkennung
(Spannungsversorgung durch
Platine)
Normaltarif-Netzanschluss für
Innengerät verwenden
(2) Stromversorgung für
Reserveheizung
Nur für ***
(3) Bedieneinheit
Nur für Fernbedienungs-
Bedieneinheitoption
Schaltkasten
(4) Brauchwasserspeicher
3-Kabel-Typ SPST
Stromversorgung für
Zusatzheizung
Nur für ***
Nur für wandmontierte Modelle
Schaltkasten
(5) Externer Fühler
Schaltkasten
(6) Bauseitig gelieferte Optionen
12 V Gleichstrom
Impulserkennung (Spannung
wird durch Platine geliefert)
230 V Wechselstrom
Spannungsversorgung durch
Platine
Dauerstrom
Auslass der
Brauchwasserpumpe
Brauchwasserpumpe
Stromzähler
Für Sicherheitsthermostat
Einschaltstrom
Maximale Belastung
Öffner
Schließer
Englisch
Safety thermostat contact: 16 V
DC detection (voltage supplied
by PCB)
Shut-off valve
SWB
(7) Option PCBs
Alarm output
Changeover to ext. heat source
If no bottom plate heater
Max. load
Min. load
Only for bottom plate heater
Only for demand PCB option
Only for digital I/O PCB option
Only for solar pump station
Options: bottom plate heater OR
On/OFF output
Options: ext. heat source output,
solar pump connection, alarm
output
Outdoor unit
Power limitation digital inputs: 12
V DC / 12 mA detection (voltage
supplied by PCB)
Refer to operation manual
Solar pump connection
Space C/H On/OFF output
Switch box
To bottom plate heater
(8) External On/OFF thermostats
and heat pump convector
Additional LWT zone
Main LWT zone
Only for external sensor (floor/
ambient)
Only for heat pump convector
Only for wired thermostat
Only for wireless thermostat
ERLQ004~008CA + EHVH/X04+08S18+26CB
Daikin Altherma – Geteiltes Niedertemperaturgerät
Übersetzung
Sicherheitsthermostat-Kontakt:
16 V Gleichstrom-Erkennung
(Spannungsversorgung durch
Platine)
Absperrventil
Schaltkasten
(7) Optionen-Platinen
Alarmausgang
Umschalter zur externen
Wärmequelle
Wenn keine
Bodenwannenheizung
Maximale Belastung
Minimale Belastung
Nur für Bodenwannenheizung
Nur für optionale Zusatz-Platine
Nur für die optionale digitale E/A-
Platine
Nur für Solarpumpenstation
Optionen: Bodenwannenheizung
oder EIN/AUS-Ausgang
Optionen: externe
Wärmequellenausgabe,
Solarpumpenanschluss,
Alarmausgang
Außengerät
Digitaleingänge für
Leistungsbeschränkung:
12 V Gleichspannung / 12 mA
Demodulation
(Spannungsversorgung durch
Platine)
Siehe Betriebsanleitung.
Solarpumpenanschluss
Ausgang für Raumkühlung/-
heizung EIN/AUS
Schaltkasten
Zu Bodenwannenheizung
(8) Externer Thermostat/
Wärmepumpenkonvektor EIN/
AUS
Zusatz-Vorlauftemperaturzone
Haupt-Vorlauftemperaturzone
Nur für externen Fühler (Boden
oder Umgebungstemperatur)
Nur für Wärmepumpen-
Konvektor
Nur für verkabelten Thermostat
Nur für kabellosen Thermostat
4P384973-1B – 2017.04