English
OPERATION: COMFORT
HANDSETS ONLY
SAV E A MEMORY POSITION
1. Move the table to the desired height.
2. Press the SAVE Key.
3. Press the Memory Position Key (e.g. 2).
The display shows S, followed by the number you pressed.
After about two seconds, the Table Top height is displayed
again. This indicates the Memory Position has been saved.
ADJUST TO A SAV ED POSITION
1. Press and hold the required Memory Position Key
(e.g. 2).
2. Wait for the table to reach the desired height.
3. Release the Memory Position Key.
The frame will move until the saved height has been rea-
ched. If you release the key before the Memory Position is
reached, or press another key, the table will stop. To conti-
nue, you must select the Memory Position again.
TROUBLESHOOTING: BASIC
HANDSETS
If your Table System is conrolled by a Basic Handset, system
information is communicated via flashes of the LED signal
light on the Handset. Possible signals are as follows:
NO LIG HT
System operating normally
• No action required.
System not connected properly
• See Assembly for connection instructions.
RED LIGHT BLINKING
System Error Warning
• Release all Keys and wait for 5 seconds. Then, try
again.
• Disconnect from the mains, check cable connections
and reconnect.
• If problem persists, perform an end position reset.
• Contact the manufacturer.
G REEN LIG HT BLINKING
System Start-up / Reset in Progress
• Wait until the LED has stopped blinking to continue.
Duty Cycle Exceeded
• Wait until the LED has stopped blinking to continue.
8
Collision Detected (ISP)
• Remove the obstruction from the Table System.
• Remove unnecessary loads from the Table Top.
• Operate the System as normal.
G REEN LIG HT FL A SHING R APIDLY
Position Reset Required.
• Perform an end position reset (page 8).
TROUBLESHOOTING:
COMFORT HANDSETS
If your Table System is conrolled by a Comfort Handset,
system information is communicated via codes on the
Handset display. Possible signals are as follows:
The display shows HOT.
Overheating protection has been activated. Wait for the
overheated components to cool.
The display shows ISP.
The system has recognized a collision. Release all Keys
and wait for the system to move back to a safe position.
The display shows CON, then ERR.
The system has recognized a connection error. Release all
Keys and wait for 5 seconds. Then, try again. If this does
not work, disconnect the system from the Power Outlet.
Check connections and reconnect the system again.
The display shows ERR, then an error number.
An internal error has occurred. Refer to the list below to
find the correct response to the error code shown.
Error Number 0 (Flashing)
Perform an End Position Reset (page 8)
Error Numbers 1, 17, 19
Disconnect the system from the Power Outlet. Ensure
all components are connected correctly. Reconnect the
system again, then operate as normal. If this fails, contact
the manufacturer.
Error Numbers 2,3,11,12,13,14,15,22,23
Release all Keys and wait for 5 seconds. Then, try again.
Contact the manufacturer if the problem persists. Do not
operate the system if components are broken.
Error Number 8
Perform an End Position Reset (page 8).
Error Number 18, 20
Contact the manufacturer.