FAULT AND DIAGNOSIS
Symptom
Product does not
start
When working , the
blades are stuck
and the white lamp
flashes
Motor burnt smell
Charging without
prompt (red light
not on)
Confirmation matters
Is it used continuously for a
long time?
Is the food stuck on the blades?
Is the host and the juice cup not
rotated in place?
The red light flickered.
The fruit pieces are too large and
have caused the blades to become
stuck.
Fruits and liquids exceed the
maximum scale rated by the
product.
Whether continuous use time
is longer
Bad connection to USB data cable.
Due to the identification
restrictions of some branded
adapters on the electrical
equipment, the actual output
voltage and current do not meet
the requirements
Take steps
Wait for the motor to cool down
before using.
Remove the remaining food and
use it again.
Install the host and juice cup in
place before starting.
Fully charge before use.
Make sure that the fruits (apples,
pears, etc.) were washed, peeled
and nucleated, and cut into small
squares of about 1cmx1cmx1cm.
Do not let the blades touch the
pulp first, then turn on and put it
in position.
Reduce the liquid capacity not
to exceed the rated capacity of
the cup.
The high-power motor is inside
the main engine. Due to the friction
of the carbon brush, it will produce
an odor, but not a product fault.
Check the connection status of
USB data cable to ensure that the
connection is normal.
Charge the product with the
universal adapter of DC5V/1A and
above, which is purchased through
regular channels.