Installation instructions, for professionals only
4. Installation
4.1. Installing the sauna control unit
Observe the following points when installing the operating unit:
The operating unit is installed on the outside wall of the cabin (with a maximum
clearance of 10 metres from the power unit) (see Fig. 1). For the installation,
a standard jigsaw or a router is required to cut out the recess for the operat-
ing unit. The operating unit can be installed both inside and outside the cabin.
*For installation inside a sauna cabin, a minimum clearance of 30 cm to the cabin
roof must be maintained (see Fig. 2).
ATTENTION!
Damage to the unit
● The operating units are protected against splashing water (protection class IP X4).
● Work on the operating unit must only be carried out using a standard screwdriver.
Using a cordless screwdriver may cause irreparable damage to the housing.
min. 30 cm
Fig. 2 Position of the operating unit
* for assembly inside the cabin
(Power unit)
*
Operating
unit
External view
p. 8/14