1. Description

1.1 Intended Purpose

The electronic control unit EMDR-10 is specifically designed for the control of gutter heating
systems. Depending on outdoor temperature and moisture in the gutter the heating cable will
only be switched on if necessary to ensure a correct drain of the snow water.

1.2 technical Data

control Unit
Supply voltage
Power consumption
Max. Switching capacity
Temperature
adjustment range
Lower limit temperature test
Operating differential
Measuring accuracy
Moisture adjustment range
Post heating time
adjustment range
Alarm relay
Moisture sensor (output)
Mounting
Low voltage directive
EMC
Terminals
Protection class
Housing
Ambient temperature range*
Ingress protection
Housing material
Weight
Dimensions
* Continuous operation must be assured and the device must be protected from the penetration
of moisture.
ambient temperature sensor
Sensor type
Ingress protection
Terminals
Sensor cable
Exposure temperature
Mounting
Moisture sensor (HaRD-45)
Sensor type
Power consumption
Ambient temperature range
Supply voltage
Connection cable
230 VAC, ±10%, 50Hz
max. 4 VA
I max 10(4)A / 230 VAC, SPST,potential 230 VAC
–3°C to +6°C (factory setting +2°C)
–25°C to –5°C (factory setting adjustment range –15°C)
±0.5 K
±1.5 K
1 (max. sensitivity) to 10 (min. sensitivity) (factory setting 5)
0 to 60 minutes (factory setting 60 minutes)
I max 2(1)A / 230 VAC, SPDT, potential-free
I max 1A / 230 VAC, SPST potential
230 VAC with fuse 5 x 20mm T1A
according to IEC127-2/V
DIN rail according to DIN EN 50022-35
EN 60730
EN 50081-1 (emission) and
EN 50082-1 (immunity)
2.5 mm
2
(stranded conductors), 4 mm
II (panel mounted)
0°C to +50°C
IP20
Noryl (self-extinguishing according to UL 94 V-0)
approx. 350 g
106 x 90 x 58 mm
VIA-DU-10
IP54
2.5 mm
2
2 x 1.5 mm
, max. 100 m (not included)
2
–30°C to +80°C
Wall mounting
PTC
9 W to 18 W
–30°C to +65°C continuous
230 VAC, ±10%, 50Hz
3 x 1.5 mm
, 4 m, the connection
2
cable can be extended to max. 100 m at 3 x 1.5 mm
2
(solid conductors)
2
5