BALI-UFF
sensors
Technical
Installation and Operating
Din
Rail
Mountable
Switching Power Supply
BAE0004
Ordering
Code
BAE
PS-XA-1W-24-012-002
Part
Number
Ill
A
Safety notes
Read
Instructions!
Before working with this unit, read these instructions
carefully and completely.
Make sure that you have
understood
all the
information!
Disconnect
system from supply
network
Before any installation,
maintenance
or modification
Disconnect
your system from the supply network. Ensure that
cannot be re-connected
inadvertently!
Before start of operation
Ensure appropriate
installation
Warning! Improper installation / operation
impair safety and
result in operational
difficulties
or complete failure of the unit.
The unit must be installed and put into service appropriately
by qualified personnel. Compliance
with the
relevant regulations
must be ensured. Before operation
begun the following conditions
must be ensured, in particular:
• Connection
to main power supply in compliance
VDEOIOOO
and
EN50178.
• With
stranded
wires:
all strands
must
be secured
terminal blocks (potential danger of short circuit)
Unit and power supply cables must be properly fused; if
. necessary a manually controlled disconnecting
be used to disengage
from supply mains.
. The
non-fused
earth
conductor
must
be connected
"O " terminal (protectionclass I).
• All output lines must be rated for the power supply output
current and must be connected
with the correct polarity.
• Sufficient air-cooling
must be ensured.
• Use in a pollution degree 2 environment.
In operation:
No modifications!
As long as the unit is in operation: do not modify the
installation! The same applies also to the secondary
of electric arcs and electric shock (fatal)!
Only (dis) connect
plug connectors
the power is off!
Convection
cooling
Do not cover any ventilation
holes!
Leave sufficient
space around the unit for cooling!
See supplementary
sheet "Technical Data" and Fig. 1
Warning:
High voltage!
Store energy!
The unit contains unprotected
conductors
carrying a lethal
high voltage, and components
storing substantial
energy. Improper handling may result in an electric shock or
serious
burn!
• The unit must not be opened except appropriately
personnel!
• Do not introduce any object into the unit!
• Keep away from fire and water!
Fig. 1
worldwide
Out-
put
Data
Fig. 2
Balluff
GmbH
Schurwaldstraße
73765
Neuhausen
Germany
Fon
+49
Fax
+49
balluff@balluff.de
www.balluff.com
Installation
Application
This unit is a primary switched-mode
for use in panel-board
applications
hazard protection).
service appropriately
Mounting
Mounting
Permissible
mounting position: see Fig. I keep free ventilation
work:
hole, leave space for cooling! Recommended
free space at all sides for ventilation / cooling:
see supplementary
Snap on support
• Tilt the unit slightly rearwards.
• Fit the unit over top hat rail.
• Slide it downward
Press against the bottom front side for locking.
Shake the unit slightly to check the locking action.
Front
elements
is
Operation
with
Indicates whether the unit is working properly. Green LED is
on in normal operation and goes out if shutdowned.
in the
Potentiometer
Setting the output voltage.
element must
to the
Connection
Connection
• Data for permitted
see enclosed leaflet " Technical Data " (See Fig. 3).
• Use only commercial
voltage and current values!
• With
flexible
secured
in the terminal.
Slde.
•
Risk
• Ensure proper polarity at output terminals!
Grounding
when
• Do not operate
EMC and safety standards
must only be operated if the PE terminalO is connectedto
the non-fused
• Secondary side is not earthed; if necessary the @ or e
terminal can be earthed optionally.
Internal
fuse
• The internal input fuse serves to protect the unit and must
not be replaced by the user. In case of an internal defect, the
unit must be returned to the manufacturer
amounts of
Removal
trained
Removal
Deatching from support rail
• Before
removal:
your system
(See Fig. 4) push the slider
lower
front edge of the unit (tipping)
BALLUFF
00
00000000
0000000
00
00000000
eee
000
00000000
0000000
0
000000000
000000
ln-
put
0000000000
QQCIÜOOO
OO
QQOOOOOOOOQOÜOO
00000000000000000
OO
OOOOOOOOOOOQOOO
00000000000000000
00000000000000000
9
a.
7158
173-0
7158
5010
power supply designed
installations
or building-in
where access to the supply is restricted (shock-
It must only be installed and put into
by qualified personnel.
to have 25mm
sheet "Technical Data".
rail (SeeFig. 2)
until it hits the stop.
indicator
I Internal
fuse
loads, cable cross-sections
and stripping:
cables designed for the indicated
cables:
make
sure
that
all stranded
cable
are
without
PE connection!
To comply with
(CE mark, approvals),
the unit
earth
conductor.
for safety reasons.
Switch
mains power
off and disconnect
from the supply
network.
downwards
(unlock),
Gently
and remove.
Fig. 3
mm
Connector size range:
AWG26
- 12 /
-
mrn2
- Connector
can
withstand
torqe at maximum
5 pound-inches
Use copper conductors
only 60 / 75'C
Max. surrounding air temperature
of 50 oc for UL 508
Fig. 4
00
O
00
z
Technical
All specifications are typical at nominal line voltage,
full load, 25QC. Unless
Data
BAE0004
Ordering
Code
BAE
Part
Number
General
Switching frequency
Isolation voltage
Isolation
resistance
Power up delay
Ambient temperature
Derating
Storage temperature
Relative humidity
Cooling
Dimension (W x L x D)
Weight
Input specifications
Input voltage
Input voltage range
Inrush
current
Line frequency
Input fuse
Output
specifications
Output voltage
. 24 VDC
Output
current
Output wattage
Voltage
trim range
Output voltage accuracy
Line regulation
Load regulation
Settling time
Temperature coefficient
„
Ripple & noise
Hold up time
DC ON
Indicator
DC LOW
Indicator
Parallel
modus
Efficiency
. 86%
Rated over load protection
Output short circuit
Approval
and standards
UL / cUL
UL 508 Listed / UL 60950-1 , UL 1310 Class 2
TÜv
EN 60950-1
CE
EN 61000-6-3,
EN 61000-3-3,
EN 61000-4-2,
EN 61000-4-5,
EN 61000-4-11
Fig. 5 Derating
100
*
75
-25
61
71
lift
Temperature ( oc ]
gee
eee
00
00
BALLUFF
otherwise
noted
PS-XA-1W-24-012-002
> 80 kHz
3.000
VAC
100 MQ
< Is
-+710C
-2.5
0/0 rc
from
+61
oc
-25
oc
+85
oc
20 - 95 % RH
. Free
air convection
41.0
x 90.0
x 114.0
mm
0.29 kg
100
- 240
VAC
85 - 264 VAC
/ 90 - 375
VDC
. 115
47 - 63 Hz
T2 A/
250
VAC
internal
1.25 Amps
30 WATTS
24.0
- 28.0
VDC
< 0.5 0/0
< 0.5%
1 ms
±0.03
0/0/ oc
50 mV
115 VAC
> 20 ms / 230
VAC
> 30 ms
Green
LED
Over
diodes
110-
140 %
Fold forward
EN 55022 Class B, EN 61000-3-2,
EN 61000-6-2,
EN 55024,
EN 61000-4-3,
EN 61000-4-4,
EN 61000-4-6,
EN 61000-4-8,
, EN 61204-3