Installation:
This product may only be installed by a qualified specialist electrician.
Before the installation is done, the connection lines to the building must be switched free from
voltage and protected against being switch on again. Take out the appropriate automatic
circuit breakers from the building installation to do this and prevent it from being switched on
again.
Protection of the exterior light with a default current circuit breaker is recommended when it is
being used in an exterior area. Follow the local installation regulations. The installation of a
leakage circuit breaker can be absolutely essential in certain locations.
Make sure that the base is suitable to support the weight of the light permanently and reliably.
Hold the light base at the desired installation position and mark the drill holes. Use suitable
screws with a maximum diameter of 6 mm for fastening the light. Make sure that no lines are
damaged.
Feed the supply lines for the power supply through the opening in the installation casing.
Now connect the connection lines at building installation to the screw terminals of the light .
Connect up the yellow-green ground wire first of all and then the other two lines. The brown
(or black) cable is usually the phase conductor, connect this to the terminal marked with an
"L". The blue conductor must be connected to the terminal marked with an "N".
Do not bend the cable, make sure that the cable and the plug are free from strain and
rotational forces. Protect all the cables and insulations from possible damage.
Check again to make sure you have made a proper connection and recluse the installation
housing. Make sure that the fitted seal is properly seated.
Push the dowels into the drilled holes and fasten the lamp casing by using suitable screws.
Make sure you have a stable and reliable fastening.
Switch on the circuit breakers of the junction box in the building again.
The illuminant cannot be exchanged.
The rating plate must not be removed.
Installation instructions Art. No. 35925
Connection
strip
Cover
Page 2 of 2
Supply line
lamp
Strain
relief
Power
supply
®
Heitronic
H. Vollmer GmbH
Allmendring 29
D-75203 Königsbach-Stein
Status 06.2014