Seite 4
Safety • Disconnect mains supply before installation or removal of sensor KLA S105 and before carrying out any maintenance or service work and ensure that it cannot be reconnected unintentionally. • If the sensor is activated, the chain actuator automatically closes the modular skylight.
Seite 6
Contents of wind and rain sensor set KLA S105 Wind and rain sensor KLA 105 Power supply unit KUX 110 Interface KLF 150 6 VELUX ®...
Seite 7
Approx 0.7 kg Protection degree: IP65 Setting of wind trigger threshold: Approx 3 to 14 m/s (±20%) Setting of wind or rain drop out delay: 10 min/20 min Setting of wind actuation delay: 2 sec/5 sec Setting of monitoring: OFF/ON VELUX ®...
Seite 8
Terminal 1: Supply voltage AC/DC Terminal 2: Supply voltage AC/DC Terminal 3: Relay (C) Terminal 4: Relay (N/C contact) Terminal 5: Relay (N/O contact) Note: Please refer to the instructions for these products that are for indoor installation only 8 VELUX ®...
Seite 10
For set-up and registration of products in interface KLF 150, please refer to directions for use and instruction leaflet for interface KLF 150. 10 VELUX ®...
Die Anleitung für den späteren Gebrauch aufbewahren und diese an den jeweiligen neuen Benutzer weitergeben. Sicherheit • Vor Montage und Demontage des Sensors KLA S105 sowie bei Wartungs- und Servicearbeiten zuerst die Netzspannung ausschalten und sicherstellen, dass diese nicht unabsichtlich wieder eingeschaltet werden kann.
Seite 14
Inhalt des Wind- und Regensensor-Sets KLA S105 Wind- und Regensensor KLA 105 Stromversorgungseinheit KUX 110 Interface KLF 150 14 VELUX ®...
Seite 15
80 x 160 x 55 mm (BxHxT, ohne Windrad) Gewicht: Ca. 0,7 kg Schutzart: IP65 Einstellung der Windauslösung: Ca. 3 bis 14 m/s (±20%) Einstellung der Wind-/Regenabfallverzögerung: 10 Min./20 Min. Einstellung der Windanzugsverzögerung: 2 Sek./5 Sek. Einstellung der Überwachung: OFF/ON VELUX ®...
Seite 16
Klemme 1: Versorgungsspannung AC/DC Klemme 2: Versorgungsspannung AC/DC Klemme 3: Relais (C) Klemme 4: Relais (Öffner bzw. Ruhkontakt) Klemme 5: Relais (Schließer bzw. Arbeitskontakt) Hinweis: Bitte Anleitung für diese Produkte befolgen, die nur für die Montage im Innenraum zugelassen sind. 16 VELUX ®...
Seite 18
Zur Einstellung und Registrierung der Produkte im Interface KLF 150 beachten Sie bitte die Anleitung und das Heftchen für das Interface KLF 150. 18 VELUX ®...
à être installés en intérieur uniquement. Produit • Le détecteur a été conçu pour fonctionner avec des produits de marque VELUX. Toute connexion à des produits d'une autre marque peut endommager le produit ou entraîner un dysfonctionnement. • Le détecteur est un produit basse tension.
Seite 22
Composant du kit anémomètre et détecteur pluie KLA S105 Anémomètre et détecteur pluie KLA 105 Unité d'alimentation électrique KUX 110 Interface KLF 150 22 VELUX ®...
Seite 23
Réglage du seuil pour le vent : De 3 à 14 m/s (±20%) Réglage du délai d'abandon vent ou pluie : 10 min/20 min Réglage du délai d'activation vent : 2 sec/5 sec Réglage de surveillance : ON/OFF VELUX ®...
Seite 24
Borne 2 : Tension AC/DC Borne 3 : Contact (C) Borne 4 : Contact (N/C) Borne 5 : Contact (N/O) Note : Merci de vous référer aux instructions pour ces produits qui sont destinés à être installés en intérieur uniquement. 24 VELUX ®...
Seite 26
Pour la configuration et l'enregistrement de produits dans l'interface KLF 150, veuillez consulter les notices de l'interface KLF 150. 26 VELUX ®...
Gem vejledningen til senere brug, og giv den videre til en eventuel ny bruger. Sikkerhed • Før montering og nedtagning af sensor KLA S105 samt ved vedligehol- delse og service skal netspændingen være afbrudt, og det skal sikres, at den ikke uforvarende kan tilsluttes igen! •...
Seite 30
Indhold i vind- og regnsensorsæt KLA S105 Vind- og regnsensor KLA 105 Strømforsyningsenhed KUX 110 Interface KLF 150 30 VELUX ®...
Seite 31
80 x 160 x 55 mm (BxHxD, uden vindhjul) Vægt: Ca. 0,7 kg Kapslingsklasse: IP65 Indstilling af udløsning ved vind: Ca. 3 til 14 m/s (±20 %) Indstilling af vind-/regnstopforsinkelse: 10 min./20 min. Indstilling af vindstartforsinkelse: 2 sek./5 sek. Indstilling af overvågning: OFF/ON VELUX ®...
Seite 32
Tilslutning til strømforsyningsenhed KUX 110 og interface KLF 150 Klemme 1: Forsyningsspænding AC/DC Klemme 2: Forsyningsspænding AC/DC Klemme 3: Relæ (C) Klemme 4: Relæ (hvilekontakt) Klemme 5: Relæ (arbejdskontakt) Bemærk: Se vejledning til disse produkter, som skal installeres indendørs. 32 VELUX ®...
Veiligheid • Sluit de stroom af voordat u begint met het installeren, verwijderen of onderhoud van de sensor KLA S105 en verzeker u ervan dat men de stroom niet terug kan aanzetten gedurende deze werkzaamheden. • Wanneer de sensor geactiveerd wordt, sluit de ketting aandrijving automatisch de modulaire lichtstraat.
Seite 38
Inhoud van het wind- en regensensor pakket KLA S105 Wind- en regensensor KLA 105 Stroomvoorzieningseenheid KUX 110 Interface KLF 150 38 VELUX ®...
Seite 39
80 x 160 x 55 mm (BxHxD, zonder de windmeter) Gewicht: Ongeveer 0,7 kg Beschermingsgraad: IP65 Instelling wind schakeldrempel: Ongeveer 3 tot 14 m/s (±20%) Instelling wind of regen uitvalvertraging: 10 min/20 min Instelling wind activatievertraging: 2 sec/5 sec Instelling bewaking: OFF/ON VELUX ®...
Seite 40
Terminal 2: Voedingsspanning AC / DC Terminal 3: Relais (C) Terminal 4: Relais (N/C contact) Terminal 5: Relais (N/O contact) Opmerking: Raadpleeg de instructies voor deze producten die enkel bedoeld zijn voor installatie binnen in de woning. 40 VELUX ®...
Seite 42
Voor het registreren en instellen van producten in de interface KLF 150 verwijzen we u graag naar de instructies en het instructieblad van de interface KLF 150. 42 VELUX ®...
ITALIANO 43-50 KLA S105 KUX 110 KLF 150 VELUX ®...
Seite 44
Sicurezza • Scollegare l'alimentazione elettrica prima di installare o rimuovere il sensore KLA S105 e prima di eseguire qualsiasi intervento di manu- tenzione o di assistenza; assicurarsi, inoltre, che non possa ricollegarsi involontariamente.
Seite 46
Contenuto del set sensore vento e pioggia KLA S105 Sensore vento e pioggia KLA 105 Unità di alimentazione KUX 110 Interfaccia KLF 150 46 VELUX ®...
Seite 47
3 a 14 m/s circa (±20%) Impostazione del ritardo di diseccitazione in base al vento o alla pioggia: 10 min/20 min Impostazione del ritardo di azionamento in base al vento: 2 sec/5 sec Impostazione del monitoraggio: OFF/ON VELUX ®...
Seite 48
Terminale 1: tensione di alimentazione CA/CC Terminale 2: tensione di alimentazione CA/CC Terminale 3: relè (C) Terminale 4: relè (contatto N/C) Terminale 5: relè (contatto N/O) Nota: consultare le istruzioni per questi prodotti che possono essere installati esclusivamente in ambienti interni. 48 VELUX ®...
Seite 50
Per la configurazione e la registrazione di prodotti nell'interfaccia KLF 150, consultare le istruzioni per l'uso e il foglio delle istruzioni per l'interfaccia KLF 150. 50 VELUX ®...
Sikkerhet • Frakoble strømtilførsel før montering eller fjerning av sensor KLA S105 og før det utføres vedlikehold eller service. Sørg for at strømmen ikke utilsiktet kan kobles på igjen.
Seite 54
Innhold i vind- og regnsensorsett KLA S105 Vind- og regnsensor KLA 105 Strømforsyningsenhet KUX 110 Interface KLF 150 54 VELUX ®...
Seite 55
80 x 160 x 55 mm (BxHxD, uten vindhjul) Vekt: Ca. 0,7 kg Beskyttelsesgrad: IP65 Innstilling av vindutløserterskel: Ca. 3 til 14 m/s (±20 %) Innstilling av forsinkelse for vind- eller regnfall: 10 min/20 min Innstilling av vindaktiveringsforsinkelse: 2 sek/5 sek Innstilling av overvåking: AV/PÅ VELUX ®...
Seite 56
Tilkobling til strømforsyningsenhet KUX 110 og interface KLF 150 Klemme 1: Forsyningsspenning AC/DC Klemme 2: Forsyningsspenning AC/DC Terminal 3: Relé (C) Terminal 4: Relé (N/C-kontakt) Terminal 5: Relé (N/O-kontakt) Merk: Vennligst se instruksjonene for disse produktene som kun er for innendørs montering. 56 VELUX ®...
Seite 58
For oppsett og registrering av produkter i interface KLF 150 henvises det til bruksanvisning og instruksjonshefte for interface KLF 150. 58 VELUX ®...
Zachowaj instrukcję do użytku w przyszłości i przekaż ją wszystkim nowym użytkownikom. Bezpieczeństwo • Przed przystąpieniem do instalacji lub usuwania czujnika KLA S105 i jakichkolwiek prac konserwacyjnych lub czynności serwisowych odłącz źródło zasilania i upewnij się, iż nie może być ono przypadkowo ponownie podłączone.
Seite 62
Zawartość zestawu czujnika wiatru i deszczu KLA S105 Czujnik wiatru i deszczu KLA 105 Zasilacz KUX 110 Interfejs KLF 150 62 VELUX ®...
Seite 63
Ok. 0,7 kg Stopień bezpieczeństwa: IP65 Ustawienie progu wyzwalania czujnika wiatru: Około 3 do 14 m/s (± 20%) Ustawienie opóźnienia wyłączenia czujnika wiatru lub deszczu: 10 min/20 min Ustawienie opóźnienia uruchamiania czujnika wiatru: 2 s/5 s Ustawienie monitoringu: WYŁ./WŁ. VELUX ®...
Seite 64
Zacisk 1: napięcie zasilania AC/DC Zacisk 2: napięcie zasilania AC/DC Zacisk 3: Przekaźnik (C) Zacisk 4: Przekaźnik (styk N/C) Zacisk 5: Przekaźnik (styk N/O) Notatka: proszę zapoznać się z instrukcjami dla tych produktów, które są przeznaczone wyłącznie do instalacji w pomieszczeniach. 64 VELUX ®...
Seite 66
Aby skonfigurować i zarejestrować produkty w interfejsie KLF 150, należy zapoznać się z instrukcją użytkowania i ulotką instruktażową interfejsu KLF 150. 66 VELUX ®...
Spara denna anvisning för senare bruk och lämna den vidare till eventu- ellt nya användare. Säkerhet • Före montering och demontering av sensor KLA S105 samt vid underhåll eller service måste strömmen vara avstängd och det måste säkerställas att den inte oavsiktligt kan slås på igen.
Seite 70
Innehåll i vind- och regnsensorsats KLA S105 Vind- och regnsensor KLA 105 Strömförsörjningsenhet KUX 110 Interface KLF 150 70 VELUX ®...
Seite 71
80 x 160 x 55 mm (BxHxD, utan vindrotor) Vikt: Ca 0,7 kg Skyddsklass: IP65 Inställning av värde för aktivering vid vind: Ca 3 till 14 m/s (±20%) Inställning av fördröjning vind-/regnstopp: 10 min./20 min. Inställning av fördröjning vindstart: 2 sek./5 sek. Inställning av övervakning: OFF/ON VELUX ®...
Seite 72
Anslutning till strömförsörjningsenhet KUX 110 och interface KLF 150 Klämma 1: Matarspänning AC/DC Klämma 2: Matarspänning AC/DC Klämma 3: Relä (C) Klämma 4: Relä (NC) Klämma 5: Relä (NO) Notera: Se anvisningarna för dessa produkter som endast är avsedd för inomhusmontering. 72 VELUX ®...