32
min: 90
DETAIL A
SCALE 3:10
10481
10314
10020
9161
7640
5800
0
min: 13771
800
max: 14588
14802
SEE DETAIL A
min: 13412
800
max: 14588
SECTION A-A
min: 90
32
DETAIL B
SCALE 3:10
SEE DETAIL B
800
SEE DETAIL C
max: 5800
0
800
32
min: 90
min: 14130
max: 14588
800
SECTION A-A
EAB16
SCALE 1:200
SEE DETAIL F
SEE DETAIL D
min: 90
32
DETAIL C
SCALE 3:10
MULTIPLE SETUP
min: 13771
max: 14588
NOTE: In the structural calculation according to EN 13782, the maximum height, as indicated on the drawing, has been applied. The wall dimensions are
provided as an indication to give a better understanding of the necessary preparations.
For certainty regarding the strength of the wall in relation to the forces from the canopy and the load from the compartment, we recommend having the
wall calculated by a structural engineer.
NOTITIE: In de statische berekening volgens EN 13782 is de maximale hoogte, zoals aangegeven op de tekening, gehanteerd. De afmetingen van de
wand zijn indicatief weergegeven om een beter beeld te geven van de benodigde voorbereidingen.
Voor zekerheid over de sterkte van de wand in relatie tot de krachten van de overkapping en de belasting vanuit het vak, adviseren wij om de wand door
een constructeur te laten berekenen.
HINWEIS: In der statischen Berechnung gemäß EN 13782 wurde die maximale Höhe, wie in der Zeichnung angegeben, berücksichtigt. Die Wandabmessungen
sind indikativ dargestellt, um einen besseren Überblick über die erforderlichen Vorbereitungen zu geben.
Für Gewissheit über die Festigkeit der Wand in Bezug auf die Kräfte der Überdachung und die Belastung aus dem Fach empfehlen wir, die Wand von einem
Statiker berechnen zu lassen.
NOTE: Dans le calcul statique selon la norme EN 13782, la hauteur maximale, comme indiquée sur le dessin, a été appliquée. Les dimensions du mur sont
données à titre indicatif afin de mieux comprendre les préparations nécessaires.
Pour garantir la solidité du mur face aux forces de la couverture et à la charge du compartiment, nous recommandons de faire calculer le mur par un ingénieur
en structure
LASERCUT ACCORDING: EN-ISO 9013-5-4-1
MATERIAL CERTIFICATE: 3.1 (OR 2.2 WHEN S235JR)
K158-1 /
GALVANIZING ACCORDING: EN ISO 1461
K158-2
BEND RADIUS UNLESS DEFINED Ri=t
TOLERANCES UNLESS OTHERWISE SPECIFIED:
DIMENSION:
ANGLE:
DETAIL F
GENERAL
ROUGHNESS
SCALE 1:4
x
Ra x
DESCRIPTION:
CT-A-1512 on concrete wall
SCALE:
UNITS
PROJECTION: MODIFIED ON: 07-05-2025
1:100
mm
KROFTMAN STRUCTURES B.V. Duplication and copying without written permission of the owner is prohibited
C
K158-1 /
K158-2
EAB16
DETAIL D
SCALE 3:10
SCALE 1:500
800
SINGLE SETUP
MATERIAL:
See List
TREATMENT:
None
STATUS: Released
MODEL NUMBER
REVISION:
TCA0240
0
x
APPROVED ON:
07-05-2025
MODIFIED BY: AVA
APPROVED BY:
BVB
MASS:
7860,9 kg
Sheet 1 of 2