Heat treated air inlet plug prolonged the life.
1.4 locations of Parts(see Figure 1)
A-Magazine
B-Safety Yoke
C-Trigger
D-Exhaust Vent
E-1/4" Air Quick Coupler
2 Special references
2.1 Instructions
The following standard is applicable to fastener driving tools;
EN792-13:2000+A1:2008"Hand-held non-electric power tools-safety
requirements -Part 13: Fastener driving tools".
This standard requires that
- only those fasteners which are specified in the operating instructions
(see TECHNICAL DATA)shall be used in fastener driving tools. The
fastener driving tool and the fasteners specified in the operating
instructions are to be considered as one unit safety system;
- quick action couplings shall be used for connection to the
compressed air system and the non-sealable nipple must be fitted at
the tool in such a way that no compressed air remains in the tool after
disconnection;
- oxygen or combustible gases shall not be used as an energy source
for compressed air operated fastener driving tools;
- fastener driving tools shall only be connected to an air-supply where
the maximum allowable pressure of the tool cannot be exceeded by
more than 10%;in the case of higher pressure ,a pressure reducing
valve which includes a downstream safety valve shall be built into the
compressed air supply;
- 4 -