Function
Green LED
Normal work
ON
Input low voltage alarm
ON
Input low voltage shut down
ON
Input over voltage shut down
ON
Over load shut down
ON
Over temperature shut down
ON
Output short-circuit
ON
Reverse connection
OFF
Red LED
Alarm
AC output
OFF
No Alarm
Yes
OFF
Alarm
Yes
ON
Alarm
No
ON
No Alarm
No
ON
No Alarm
No
ON
Alarm
No
ON
No Alarm
No
OFF
No Alarm
No
Please stop using and charge the battery. Or replace with new batteries.
When the input voltage rises to 12V +/- 0.3V, the inverter will automatically resume operation.
Please stop using and charge the battery. Or replace with new batteries.
When the input voltage rises to 12V +/- 0.3V, the inverter will automatically resume operation.
Please stop using it and check if the battery is damaged. Or replace with new batteries.
When the input voltage drops to
14.5V ~ 15.5V,
Reduce load power to within rated range .Manually restart the inverter
Please stop using and cooling the inverter.
When the temperature drops, the inverter will automatically resume operation.
Please stop using it and check the load. Restart the inverter manually after troubleshooting.
Maybe reverse connection will blow the fuse please replace the fuse with same specification;
Maybe reverse connection will cause irreparable damage to the inverter!
2
Restart work method
/
the inverter will automatically resume operation.