Herunterladen Diese Seite drucken

Bosch LTC 8780/60 Anleitung Seite 34

Ltc 8780 serie

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 71
20
en | PINOUTS
1
4
6
9
12
12
9
C
Fig. 5.3 LTC 8780 Series Configured for Block Limited Transmission
Referemce
Description
1
Main Allegiant Matrix Switcher
2
Remote Site A, cameras 1-64
3
Pan/tilt camera
4
LTC 8568 signal distribution unit
5
Allegiant Series receiver/driver
6
Biphase data
7
LTC 8780 Series configured as Signal Distribu-
tion Unit
8
RS-232 compatible link
S101
1 Baud
2 Baud
3 X
4 ON
x = Don't Care
Table 5.1 LTC 8780 DIP Switch Settings - A
F01U066145 | 1.0 | 2007.04
A
8
7
11
11
15
15
1 - 64
11
11
15
15
65 - 128
7
8
S102
S103
1 ON
1 OFF
2 OFF
2 ON
3 OFF
3 OFF
4 ON
4 OFF
Instruction Manual
B
2
13
13
15
15
D
14
14
13
13
15
15
Referemce
9
10
11
12
13
14
15
A
S104
S105
1 OFF
1-3 see
Figure 5.6
2 OFF
on page 24
3 OFF
4 OFF
4 X
LTC 8780 Series
3
5
6
10
10
3
6
5
10
10
Description
Code In
Code Out
Pan/tilt/zoom data for cameras
specified
Main switcher control site
LTC 8780 Series data converter unit
(RS-232 to biphase mode)
Remote Site B, cameras 65-128
RS-232 port
Bosch Security Systems, Inc.

Werbung

loading

Diese Anleitung auch für:

Ltc 8780/50