Herunterladen Diese Seite drucken

Weidmuller PV-Stick - Installationsanleitung

Pv-anschlussstecker
Installationsanleitung /
Installation Instructions
PV-Anschlussstecker / PV-Connector
PV-Stick -
(Stift / Male)
PV-Stick +
(Buchse / Female)
Technische Daten / Technical data
Dauergebrauchstemperatur
Continuous operating temperature
-40 °C .... + 85 °C
Bemessungsspannung
Rated voltage
1500 V DC
Bemessungsstrom
Rated current
30 A
Schutzgrad gesteckt
Protection degree mated
IP65 / IP68 (1 m, 1 h)
Schutzgrad offen
Protection degree unmated
IP2x
Schutzklasse
Protection class
II
Leiterquerschnitt
Wire cross section
4 mm² ... 6 mm²
Kabeldurchmesser
Cable diameter
5.4 - 7.6 mm
Überspannungskategorie
Overvoltage category
III
Verschmutzungsgrad
Polution degree
2 / 3
innerhalb / außerhalb
inside / outside
Clearance and creepage
Luft- & Kriechstrecke gem.
DIN EN 60664-1:2007
distance acc.
Power loss /
Übergangswiderstand gem.
IEC 62852:2014+Amd.1:2020
Contact resistance acc.
geprüft nach / tested acc. to
Zertifiziert
Certified
IEC 62852:2014+Amd.1:2020
Bemessungsstoßspannung
Rated impulse voltage
16 kV
Anschlusstechnologie
Connection technologie
SNAP IN
Montagetemperatur
Installation temperature
+10 °C ... +40 °C
Obere Grenztemperatur
Upper limitin temperature
+115 °C
Sicherheitshinweise
– Vor allen Arbeiten muss die Anlage spannungsfrei und stromlos geschaltet und gegen Wieder-
einschalten gesichtert werden.
– Das Produkt darf nur von qualifiziertem Fachpersonal installiert werden, das mit den nationalen
und internationalen Gesetzen, Richtlinien und Standards des Verwendungsbereichs vertraut ist.
Bestimmungsgemäßer Gebrauch
Der Stecker ist ausschließlich zum Einsatz in Photovoltaikanlagen innerhalb der beschrieben Spe-
zifikation vorgesehen. Der Stecker kann nur für Verbindungen innerhalb eines Strings verwendet
werden. Beim Einsatz bis 1.500 V darf der Stecker nur zusammen mit Leitern verwendet werden, die
für diesen Einsatzzweck freigegeben sind. Jede abweichende Verwendung kann zu schweren Perso-
nen- und Sachschäden führen. Zum bestimmungsgemäßen Gebrauch gehört auch das Beachten der
Installationsanleitung.
Umgebungsbedingungen
Die Produkte dürfen nur in sauberem Zustand montiert werden. Falls erforderlich, sollten offene Ste-
cker bzw. Buchsen mit Staubschutzkappen vor Verschmutzung geschützt werden (s. Zubehör).
– Der montierte PV-Stick darf nicht direkt auf der Dachhaut liegen.
– Der montierte PV-Stick darf keiner dauerhaften mechanischen Belastung ausgesetzt sein. Zur
Zugentlastung sollten alle Leitungen mit Kabelbindern gesichert werden.
Anschließbare PV-Leitungen
Die anzuschließenden PV-Leitungen müssen folgende Anforderungen erfüllen:
– Zulassung gemäß IEC 62930:2017
– Verzinnter Kupferleiter Klasse 5 gemäß IEC 60228:2005
– Mantelmaterial entsprechend Isolierstoffgruppe II gemäß IEC 60664-1:2020
Safety notice
– Prior to work the device must be disconnected from the power supply and potected against re-
connection and it must be de-energized.
– This product may only be installed by qualified personnel familiar with the national and interna-
tional laws, directives and standards that apply to this filed of application.
Intended use
The connector is intended for use only in photovoltaic systems within the specifications described.
The connector can only be used for connections within one string. In applications up to 1,500 V the
connector may only be used together with cables that are released for this purpose. Any other usage
can lead to serious personal injury and damage to property. The observance of this installation inst-
ructions is part of the intended use.
Ambient conditions
The components shall be clean during installation. If neccessary please use the dust cap (see acces-
sories) to protect it from dirt.
– The installed PV-stick shall not be located directly on the roof panel.
– The installed PV-stick shall not be exposed to permanent mechanical load. All cables shall be
fixed using cable ties or any kind of strain relief.
Connectable PV cables
The PV cables to be connected must meet the following requirements:
– Appoval according to IEC 62930:2017
– Tinned copper conductor class 5 according to IEC 60228:2005
– Sheathing material comlpying with material group II according to IEC 60664-1:2020
Bestelldaten / Order data
Buchse / Female
VPE
Packaging unit
Best.-Nr. / Order No.
10
1303450000
50
1303460000
200
1303470000
PV-Stick Set
1 x Buchse und Stift / 1 x Female and male
1422030000
Zubehör / Accessories
Buchsengehäuse
Female housing
Box Version
box version
Buchsenkontakt
Female contact
Stiftstecker
Male housing
Box Version
box version
Stiftkontakt
Male contact
Staubschutzkappen
Dust protection cap
für Buchse und Stift
for female and male
Sicherungsclip
Locking clip
multi-stripax PV
multi-stripax PV
Abisolier- und
Stripping and cutting
Schneidwerkzeug
tool
MULTITOOL
MULTITOOL
PV SET
PV SET
Stift / Male
Best.-Nr. / Order No.
1303490000
1303500000
1303510000
Best.-Nr. /
Order No.
1530630000
1530670000
1530640000
1530680000
1254870000
1328150000
1190490000
2771530000
loading

Inhaltszusammenfassung für Weidmuller PV-Stick -

  • Seite 1 Sicherheitshinweise Bestelldaten / Order data Installationsanleitung / Installation Instructions – Vor allen Arbeiten muss die Anlage spannungsfrei und stromlos geschaltet und gegen Wieder- Buchse / Female Stift / Male einschalten gesichtert werden. – Das Produkt darf nur von qualifiziertem Fachpersonal installiert werden, das mit den nationalen und internationalen Gesetzen, Richtlinien und Standards des Verwendungsbereichs vertraut ist.
  • Seite 2 PV-Stick montieren / Installing the PV-Stick Leiter einführen / Inserting the cable Leiter verschrauben / Connecting the cable Leiter vorbereiten / Preparing the cable min. 15,0 mm max. 16,5 mm PV-Stick austauschen / Replacing the PV-Stick GEFAHR DANGER Gefährliche Spannung! Hazardous electrical voltage! Nicht unter Last trennen! Do not disconnect under load!

Diese Anleitung auch für:

Pv-stick +13034500001303490000130346000013035000001303470000 ... Alle anzeigen