EN
Specifications
Range
Accuracy
Device precision
Flow rate pump (l/h)
Flow rate pump (SPA model only)
Power supply
Consumption (W)
Probe calibration
Pump state
Max. back-pressure
Relay contact (number 3)
Fuse
Weight
Dimensions (W–H–D)
Default parameters
n
Item
1
Language
2
Set Point value
3
Dosing method
4
OFA Time
5
Calibration
6
Circulation pump
7
Dosing type
8
IN Freq.
9
Flow Input
10
Power ON Delay
11
Flow Delay
0000139978 · EasyChem Double and Plug version | pH · ORP
SPECIFICATIONS
Value
EN
7.4 pH
Acid (pH)
OFF
Full
ON
PROP; Relay Aux1, Aux2, Aux3 are disabled
OFF
NO (normally open) (Reed Sensor)
OFF
OFF
EASY-CH-DPHRXG / EASY-CH-DPHRXGS
0-14pH; -99 -1000mV; 0...+55°C
±0.02pH, ±3mV; ±0.5°C
± 0.1 pH; ±10mV; ±1°C
220-240 VAC 50-60 Hz
Pause – Supply
250 Vac 10A (resistive load)
500 mA (fast)
212 x 303 x 113 mm
Measure alarm ranges default parameters
n
1
700 mV
2
Low (Redox)
3
4
5
6
1.5 l/h
1.5 l/h
28 Watt
Automatic
1.5bar
3.5 Kg
Item
Temp. Measure min
Temp. Measure Max
pH Measure
min
pH Measure
Max
ORP Measure min
ORP Measure Max
Page 4 on 20
Limits
+ 10°C
+ 38°C
6 pH
8.0 pH
+450 mV
+850 mV