1. TECHNICAL PARAMETER:
Product Model:
ForestFrog-15
Type of Protection:
Ex db, Ex tb
Protection Standard
EN 60079-0:2018, EN 60079-1:2014, EN 60079-
31:2014, IEC 60079-0:2017, IEC 60079-1:2014, IEC
60079-31:2013, EN 55015, EN 61547, EN 61000-3-2,
EN 61000-3-3, EN 60598-1, EN 60598-2-5, EN
62031, EN 62493, IEC 62321-4, IEC 62321-5, IEC
62321-6, IEC 62321-7-1, IEC 62321-7-2, IEC 62321-8
Area Classification:
Zone 1 and Zone 2 Areas to (IEC) EN 60079-10-1,
Zone 21 and Zone 22 Areas to (IEC) EN 60079-10-2
Installation:
(IEC) EN 60079-14
Certificate:
EPT 18 ATEX 2977 X/IECEx CQM 15.0039X/CML 22
UKEX 1362 X
Equipment Coding:
Ex db IIC T* Gb,Ex tb IIIC T* Db
Temperature Class
15 Watt
-20°C ≤ Ta ≤ +55°C
ATEX Coding
II 2 G / II 2 D
IP Rating:
IP66 (IEC)EN 60529
CE Mark
The CE marking of this product applies to EU direc-
tives 2014/35/EU, 2014/30/EU, 2012/19/EU and
2011/65/EU and 2014/34/EU/SI 2016 No. 11017
respectively.
The Equipment is declared to meet the provisions of
the ATEX directive(2014/34/EU) by reason of the EU
Type Examination and compliance with the Essential
Health and Safety Requirements
© Tiroled Austria GmbH
Ta
T class (gas)
Dust (°C)
T6
Manufacturer:
SHENZHEN KHJ SEMICONDUCTOR LIGHTING CO., LTD.
4-5 Floor, Building 1, Chuangxin Industrial Park,
Xintian community, Guanlan, Longhua new district,
Shenzhen ,China
www.khjled.com
Importer:
TiroLed Austria GmbH
Schatzparkweg, Oberau 304
6311 Wildschönau
Österreich
Telefon: +43 5339 208 10
E-Mail:
info@tiroled.com
Internet: www.tiroled.com
1. TECHNISCHE PARAMETER:
Produktmodell:
Schutzart:
Schutz Standard:
Klassifikation:
Installation:
Zertifikat:
Einteilung:
Temperature Class
80°C
15 Watt
ATEX Kodierung
IP Rating:
CE Kennzeichnung:
1 of 7
ForestFrog—15
Ex db, Ex tb
EN 60079-0:2018, EN 60079-1:2014, EN 60079-
31:2014, IEC 60079-0:2017, IEC 60079-1:2014, IEC
60079-31:2013, EN 55015, EN 61547, EN 61000-3-2,
EN 61000-3-3, EN 60598-1, EN 60598-2-5, EN
62031, EN 62493, IEC 62321-4, IEC 62321-5, IEC
62321-6, IEC 62321-7-1, IEC 62321-7-2, IEC 62321-8
Zone 1 u. Zone 2 Areas to (IEC) EN 60079-10-1,
Zone 21 u. Zone 22 Areas to (IEC) EN 60079-10-2
(IEC) EN 60079-14
EPT 18 ATEX 2977 X/IECEx CQM 15.0039X/CML 22
UKEX 1362 X
Ex db IIC T* Gb,Ex tb IIIC T* Db
Ta
T class (gas)
-20°C ≤ Ta ≤ +55°C
T6
II 2 G / II 2 D
IP66 (IEC)EN 60529
Die CE-Kennzeichnung dieses Produkts gilt für die
EU-Richtlinien 2014/35/EU, 2014/30/EU, 2012/19/
EU and 2011/65/EU and 2014/34/EU/SI 2016 No.
11017
Aufgrund der EU-Baumusterprüfung und der Einhal-
tung der grundlegenden Gesundheits- und Sicher-
heitsanforderungen wird erklärt, dass das Gerät den
Bestimmungen der ATEX-Richtlinie (2014/34/EU)
entspricht
Dust (°C)
80°C
02. Sept. 2024