Measuring
principle NDIR (maintenance-free) of ± 30ppm
of measured value
CO2 measuring range
from 0 - 10.000 ppm
Measurement types
Temperature and humidity measurement
(e.g. mold prevention)
Acoustic alarm
switchable
Visual alarm
through interactive colors: 360° view
Response time
< 20 seconds
Dimensions
85 x 85 x 140 mm
Indicator light colors
red > 1500 ppm
yellow 1000...1500 ppm
(Threshold values adjustable)
green < 1000 ppm
Sensor lifetime
min. 15 years
Power supply
USB-C power supply (5V DC / max. 1500mA)
+ connection cable
Housing material
ASA / acrylic glass
Weight
approx. 315 grams
(Without power supply and connection cable)
Connectivity
WLAN radio standard, IEEE 802.11 b/g/n
Radio frequency 2.4 GHz; up to 150 Mbps
Bluetooth® EDR with the modulations π/4 DQPSK
and 8DPSK
Open API
REST interface for integration into own environments
Marking
CE mark
Customs tariff number
85318070