Installation
First please confirm if your gas is heavier than air, or lighter than air. Heavier gases: LPG etc;
Lighter gases: natural gas, marsh gas etc.
2.
Choose a suitable position to install the detector according to the gas specific gravity. For
detecting heavier gases, installation height: 0.3—1 .Om from floor, within the radius of 1.5 m from
gas source. For detecting lighter gases, installation height: 0.3—1 .Om from ceiling, within the
radiusof 1.5 m fromgas source(refer to image[A]).
Fix the attached installing base into a wall firmly with screws and hang the detector.
4.
When installing at home, keep the detector away from gas cookers to avoid being roasted by
flame. Do not install the detector in places with heavy smoke and oil which may cause false
alarms or block the gas convection holes of the detector, which affects the detector sensing
sensitivity. Also do not install it near to exhaust fans, windows, doors, and places with heavy
vapour in bathroom.
5.
Correctly connect the wires. All wiring and installation must accord with the National and Local
effective laws and criteria. Improper connection will cause the detector not alarm on gas leaking.
Operating
instruction
The detector will work just simply by plug-in.
2.
After plug-in, the power LED constant on green. With a "Di' sound from buzzer, the detector
enters into warming up state. Red and yellow LEDs flash alternatively. 3 minute s later, the LEDs
go out and the detector goes into normal working state. Testing with gas is forbidden during
warming
up.
When a combustible gas leak happened and reached the given alarm level, the alarm LED will
flash red and the buzzer will give out "Di... Di..." alarm sounds. Meanwhile, the detector will send
out wireless alarm signal.
4.
The detector checks sensor failure automatically during working. For sensor failure, the Fault
LED on yellow constantly along with buzzer sounding. For this situation, unplug the detector and
contact your vendor. Do not take apart the detector or try to repair it by yourself.
2262
or 1527
100 m (open area)
AC power:
power
LED constant
Alarm: Alarm
LED flashing
Sensor
Failure:
Fault LED constant
110 x 70 x 40 mm
RDT
401
green
red rapidly
yellow
21