EN
Safety Instructions and Warnings
!
!
Do not open the device!
•
Before any installation, or maintenance, ensure that the main switch is
•
switched off and prevented from being switched on again.
The device can be installed and put into service by qualified personnel only.
•
Never work on the device if power is applied.
•
Risk of electric arcs and electrical shock, which can cause death, severe
•
personal injury or substantial property damage.
The unit must be connected to the mains supply in compliance with national
•
regulations (e.g. VDE0100 and EN50178). All wire strands must be fastened
in the terminal blocks. (Potential danger of contact with the case).
All input and output wires must be properly rated for the power supply and
•
must be connected with the correct polarity. Fig.1
The Power Supply wiring must be sufficiently fused.
•
Do not introduce any objects into the device.
•
Keep away from fire and water.
•
The internal fuse is not accessible. If this internal fuse has blown, the power
•
supply has an internal defect and, for safety reasons, must be shipped to the
local distributor.
The device is designed for use in a clean, dry environment.
•
The device shall be mounted in an enclosure in the end application. The
•
power supply is not accessible in operation.
Installation Instructions
The standard mounting orientation is with input terminals (I/P) at the bottom.
Recycling
The device contains elements that are suitable for recycling, and components
that need special disposal. You are therefore requested to make sure that the
device will be recycled at the end of its service life.
Identification of Features Fig.1
1. Input Connection Terminal
N
(White)
L
2. Input Connection t Terminal
(Black)
+
3. Output Connection Terminal
(Red)
-
4. Output Connection Terminal
(Black)
Order Code
SPECIFICATIONS
TIW 24-
112
124
Nominal Input Voltage
100 - 240 VAC
Nominal Input Current
0.42-0.32 A
0.45-0.30 A
93 - 264 VAC
Operational Input Voltage Range
47 - 63 Hz
Input Voltage Frequency Range
Inrush Current (115/230 VAC)
12/24 A
Circuit Breaker Rating / Characteristic
6 A / C
Max. Output Power
24 W
Output Voltage
12 V
24 V
Max. Output Current
2.0 A
1.0 A
Power Factor λ
0.41
0.44
Typical Efficiency (230 VAC)
83%
85%
Operating Temperature Range
-25°C to +50°C
Max. Case Temperature Tc
90°C
90°C
Fig.3
Output Power Derating - Input Voltage
Protection Class
Class II
Degree of Protection
IP67
0.25 mA
Leakage Current (max)
Network Configuration
TN-S, TN-C, TT, IT
Humidity
5 - 95%, no condensation
Storage Temperature
-40°C to +85°C
Maximum Altitude
3000 m
Rev. Oct 04,2021
Sicherheitsinstruktionen und Warnungen
DE
!
!
Das Gerät nicht öffnen!
•
Vor Installations- oder Wartungsarbeiten muss sichergestellt sein, dass der
•
Hauptschalter der Applikation ausgeschaltet ist und ein Einschalten
verhindert wird.
Das Gerät darf nur von qualifiziertem Personal installiert und in Betrieb
•
genommen werden.
Nie am Gerät arbeiten, wenn Spannung angelegt ist.
•
Es besteht das Risiko eines elektrischen Schlages und Entstehung von
•
Lichtbögen, welche lebensgefährliche Körperverletzungen oder
Sachschäden verursachen können.
Der Anschluss des Geräts an das Versorgungsnetz muss den nationalen
•
Vorschriften entsprechen (z.B. VDE0100 und EN50178). Alle Drähte
müssen an den Anschlussklemmen befestigt sein (Potentielles Risiko eines
Kontakts mit dem Gehäuse).
Alle Verdrahtungen am Eingang und Ausgang müssen entsprechend dem
•
Netzteil ausgelegt und mit der richtigen Polarität verbunden sein. Fig.1
Die Stromversorgung muss ausreichend abgesichert sein.
•
Es dürfen keine Gegenstände in das Gerät eingeführt werden.
•
Von Feuer und Wasser fernhalten.
•
Die interne Sicherung ist nicht zugänglich. Falls diese auslöst hat die
•
Stromversorgung einen internen Defekt und muss aus Sicherheitsgründen
zum lokalen Distributor zurückgeschickt werden.
Das Gerät ist für den Gebrauch in sauberer und trockener Umgebung
•
bestimmt.
Das Gerät muss in der Endapplikation in einem Gehäuse montiert sein. Die
•
Stromversorgung darf im Betrieb nicht zugänglich sein.
Einbauanweisungen
Die Standardmontageausrichtung ist mit den Eingangsanschlüssen (I/P) auf der
unteren Seite.
Entsorgung
Das Gerät enthält Bestandteile, welche zum Recycling geeignent sind und
Komponenten, welche fachgerecht entsorgt werden müssen. Stellen Sie daher
sicher, dass das Gerät nach Gebrauch korrekt entsorgt wird.
Funktionsbeschreibung Fig.1
N
1. Eingangsanschlussklemme
(Weiss)
L
2. Eingangsanschlussklemme
(Schwarz)
+
3. Ausgangsanschlussklemme
(Rot)
-
4. Ausgangsanschlussklemme
(Schwarz)
Bauteilbezeichnung
SPEZIFIKATIONEN
TIW 24-
112
124
Nominale Eingangsspannung
100 - 240 VAC
Nominaler Eingangsstrom
0.42-0.32 A
0.45-0.30 A
93 - 264 VAC
Eingangsbetriebsspannungbereich
47 - 63 Hz
Eingangsspannungsfrequenzbereich
Einschaltstrom (115/230 VAC)
12/24 A
Sicherungsnennwert / Charakteristik
6 A / C
Max. Ausgangsleistung
24 W
Ausgangsspannung
12 V
24 V
Max. Ausgangsstrom
2.0 A
1.0 A
Leistungsfaktor λ
0.41
0.44
Typischer Wirkungsgrad (230 VAC)
83%
85%
Betriebstemperaturbereich
-25°C bis +50°C
Max. Gehäusetemperatur Tc
90°C
90°C
Fig.3
Ausgangsleistungsminderung - Eingangsspanung
Schutzklasse
Klasse II
Schutzart
IP67
0.25 mA
Kriechstrom (max)
Netzstruktur
TN-S, TN-C, TT, IT
Luftfeuchtigkeit
5 - 95%, keine Betauung
Lagertemperatur
-40°C bis +85°C
Maximale Höhe
3000 m
Consignes de sécurité et avertissements
FR
!
!
Ne pas ouvrir l'appareil!
•
Avant toute installation ou action d'entretien, s'assurer que l'interrupteur
•
principal soit éteint et sécurisé contre toute remise en marche.
L'appareil peut être installé et mis en service uniquement par du personnel
•
qualifié.
Ne jamais travailler sur l'appareil, quand il est mis sous tension.
•
Risque d'arcs et de chocs électriques, qui peuvent provoquer des blessures
•
corporelles graves, la mort ou des dégâts matériels importants.
L'appareil doit être branché à l'alimentation dans le respect des
•
réglementations nationales (par ex. VDE0100 et EN50178). Tout brin de fil
doit être fixé dans les borniers (Risque potentiel de contact avec le casier).
Tous les fils d'entrée et de sortie doivent être correctement étalonnés pour
•
le bloc d'alimentation et être branchés à la bonne polarité. Fig.1
Le câblage d'alimentation doit être protégé par des fusibles de calibre
•
suffisant.
Ne pas introduire d'objets dans l'appareil.
•
Tenir à l'écart du feu et de l'eau.
•
Le fusible interne n'est pas accessible. Si ce fusible interne est grillé, le bloc
•
d'alimentation présente un défaut interne et, pour des raisons de sécurité, il
doit être expédié au distributeur local.
L'appareil est conçu pour être utilisé dans un environnement propre et sec.
•
L'appareil doit être monté à l'intérieur d'une enceinte dans l'application
•
finale. Pendant le fonctionnement, le bloc d'alimentation n'est pas
accessible.
Instructions d'installation
L'orientation standard du support prévoit que les bornes d'entrée (I/P) se
trouvent en bas.
Recyclage
L'appareil contient des éléments appropriés au recyclage et des composants
nécessitant une mise au rebut particulière. L'utilisateur est donc prié de s'assurer
que l'appareil sera recyclé à la fin de sa durée de vie.
Identification des caractéristiques Fig.1
1. Borne de branchement d'entrée
N
(Blanc)
L
2. Borne de branchement d'entrée
(Noir)
+
3. Borne de branchement de sortie
(Rouge)
-
4. Borne de branchement de sortie
(Noir)
Code de commande
SPÉCIFICATIONS
TIW 24-
112
124
Tension nominale d'entrée
100 - 240 VCA
Courant nominal d'entrée
0.42-0.32 A
0.45-0.30 A
93 - 264 VCA
Plage de tension d'entrée opérationnelle
47 - 63 Hz
Plage de fréquence de tension d'entrée
Courant d'appel (115/230 VCA)
12/24 A
Valeur nominale / caractéristiques du disjoncteur
6 A / C
Puissance de sortie maxi
24 W
Tension de sortie
12 V
24 V
Courant de sortie maxi
2.0 A
1.0 A
Facteur de puissance λ
0.41
0.44
Rendement typique (230 VCA)
83%
85%
Température de fonctionnement
-25°C á +50°C
Température maxi du boîtier Tc
90°C
90°C
Fig.3
Réduction de la puissance de sortie - Tension d'entrée
Classe de protection
Classe II
Degré de Protection
IP67
0.25 mA
Courant de fuite (maxi)
Configuration du réseau
TN-S, TN-C, TT, IT
Humidité
5 - 95%, sans condensation
Température de stockage
-40°C á +85°C
Altitude maximale
3000 m
Fig.1
1
2
8.0
6.9
3.6
I/P
O/P
[mm²]
[AWG]
0.82
18
1
18
2
0.82
0.52
20
3
4
0.52
20
5.0±2
3
4
mm
P
- V
Fig.3
(O/P)
(I/P)
P/Pmax
[%]
100
90
80
70
60
50
93
100
115
132
187
240
264
V
[VAC]
(I/P)
Specifications can be changed without notice
TIW 24
Power Supply Unit for
Home & Office applications
www.tracopower.com/overview/tiw
Fig.2
56.0
32.0
30.8
Ø3.2 (x2)
3
6.0 max (x2)
kg
0,10kg
mm
Fig.4
Mounted in standard flush box
In Standard-Unterputzdose montiert
Monté dans un boîtier encastré standard
Montado en caja para empotrar estándar
Montato in scatola da incasso standard
Устанавливается в стандартную коробку