Overcurrent Protection
If the current exceeds 35A, the charging station will shut off
power and automatically resume after a 1-minute delay.
Overvoltage Protection
When the voltage exceeds 275V, the protection system
activates and will automatically restore power once the voltage
stabilizes.
Undervoltage Protection
If the voltage falls below 88V, the protection system initiates
and will automatically restore power when the voltage stabilizes.
Temperature Protection (Overtemperature Protection,
Low-temperature Protection)
If the temperature exceeds 83°C, the protection system
activates, and power is automatically restored when the
temperature drops to 80°C.
Grounding Requirement
The system requires a proper ground connection for safe
charging.
Emergency Stop Protection
Pressing the emergency stop switch will disconnect power
output from the charging station. Normal operation is restored
when the emergency stop switch is reset.