Description
EN
Slight increase
of outlet pres-
sure & relief
valve does not
open
Slight increase
of outlet pres-
sure
Slight drop of
outlet pressure
Heavy drop of
outlet pressure
Heavy drop of
outlet pressure
Outlet Pres-
sure to high
Outlet pres-
sure increase
immediately
all the way to
the stop or
outlet pressure
increases and
gets slowly
higher than set
value and relief
valve opens
Noise during
operation
Reason
Solution
Inlet pressure
No failure, nor-
drop
mal operating
state
Diff erence
No failure, nor-
between fl ow
mal operating
pressure (with
state
gas fl ow) and
Zero Pressure
(without gas
fl ow)
Diff erence
No failure, nor-
between fl ow
mal operating
pressure (with
state
gas fl ow) and
Zero Pressure
(without gas
fl ow)
Required
Choose new
fl ow to high
pressure
for pressure
regulator for re-
regulator
quired pressure
and fl ow
Leakage in
Check process
process gas
gas tubing
tubing
Wrong set-
Adjust pressure
tings for pres-
regulator set-
sure regulator
tings, readjust
pressure
regulator, main-
tenance
Pollution or
Repair by
damage of
manufacturer
pressure
regulator seat
"Creap"
Required
Choose new
fl ow too high
pressure
for pressure
regulator for re-
regulator
quired pressure
and fl ow
Valve
Cylinder
Regulator
18/286
Line
Gas
Regulator
Supply Panel