As the flame lights up, keep the valve button pushed for 10
seconds approx. Should the heater stop when the valve button
has been released, wait one minute and repeat the starting
operation keeping the valve button pushed for a longer time.
Regulate the gas flow pressure according to the thermal power
desired, by turning the wheel of the pressure reducer
anticlockwise to increase the pressure or clockwise to decrease.
Contact your supplier should any problem continue.
CAUTION
If ignition is difficult or irregular before repeating the ignition
operations make sure that the fan is not locked and the air inlet
and outlet are unobstructed.
SWITCH OFF
To stop the heater, shut off the gas cylinder tap. Let the fan run
until the flame shuts down and then turn the fan switch to
position OFF.
ODOR FADE WARNING
WARNING
Asphyxiation Hazard
Do not use heater for heating human quarters.
Do not use in unventilated areas.
The flow of combustion and ventilation air must not be
obstructed.
Proper ventilation air must be provided to support the
combustion air requirements of the heater being used.
Lack of proper ventilation air will lead to improper
combustion.
Improper combustion can lead to carbon monoxide
poisoning leading to serious injury or death. Symptom of
carbon monoxide poisoning can include headaches
dizziness and difficulty in breathing.
FUEL GAS ODOR
LP gas and natural gas have manmade odorants added
specifically for detection of fuel gas leaks.
If a gas leak occurs you should be able to smell the fuel gas.
Since Propane (LP) is heavier than air you should smell for the
gas odor low to the floor. ANY GAS OROR IS YOUR SIGNAL
TO GO INTO IMMEDIATE ACTION!
Do not take any action that could ignite the fuel gas. Do not
operate any electrical switches. Do not pull any power
supply or extension cords. Do not light matches or any
other source of flame. Do not use your telephone.
Get everyone out of the building and away from the area
immediately.
Close all propane (LP) gas tank or cylinder fuel supply
valves, or the main fuel supply valve located at the meter if
you use natural gas.
Propane (LP) gas is heavier than air and may settle in low
areas. When you have reason to suspect a propane leak,
keep out of all low areas.
Use your neighbor's phone and call your fuel gas supplier
and your fire department. Do not reenter the building or
area.
Stay out of the building and away from the area from the
area until declare safe by the firefighters and your fuel gas
supplier.
FINALLY, let the fuel gas service person and the firefighters
check for escaped gas. Have them air out the building and
area before you return. Properly trained service people
must repair any leaks, check for further leakages, and then
relight the appliance for you.
MAINTENANCE
The repairs or maintenance operations must only be
carried out by qualified personnel.
The unit must be checked by a qualified technician at least
once a year.
Regularly check the conditions of gas hose, and gas
regulator if it must be replaced only use original spare
parts.
Before starting any maintenance operation on the heater
disconnect from both gas and electrical suppliers.
If the unit has not been used for a long period we advise
that a technician carries out a general check up before
using. It is important to control the following:
Periodically check the gas supply hose conditions and,
should it be changed, use only original spare parts.
Check the starting electrode position A=5-7mm
Check the connections of the safety thermostat and of the
thermocouple: they must always be clean.
If necessary clean the fan blade and the inside of the heater
using compressed air.
Servicing instructions
These instructions are intended to be used only by
competent persons and they shall provide detailed
instructions for carrying out all servicing operations
authorized by the manufacturer.
All special tools, materials or servicing aids necessary for
the correct servicing of the appliance shall be specified
In particular, the instructions shall specify:
that the appliance be checked for soundness
where applicable, that the appliance be checked for setting
pressure
the method for verifying the correct operation of the burner:
the precautions to be taken if the appliance cannot be left
in a safe condition;
Package included: 1 set of regulator and hose, 1 pc heater
body and 1 pc handle.
ELECTRICAL POWER SUPPLY
HEATER POWERED WITH THE RECHARGEABLE BATTERY
USE ONLY ORIGINAL RECHARGEABLE BATTERIES WITH
THE VOLTAGE RATING INDICATED ON THE TECHNICAL
DATA PLATE AFFIXED TO THE HEATER.
TROUBLESHOOTING
FUNCTIONING
CAUSES
ANOMALIES
The motor does
Battery ow (if
not start
battery-powered)
Defective power
supply or battery
Faulty motor
The flame does
Gas cylinder
not ignite
empty
Regulator safety
valve blocked
SOLUTION
Charge the
battery
After-sales
assistance
After-sales
assistance
After-sales
assistance
Replace the gas
cylinder
Press the
regulator gas
release button