• In case of damaged parts, it is preferable to purchase replacement parts from the
manufacturer. Use only original standard parts. Failure to do so will void your warranty.
Electrical
• Please disconnect all power supplies during installation.
• It is recommended that the water treatment unit be installed in a bypass configuration so that:
o Chlorine and acid pumps cannot operate if the filtration pump is not working. This can
be done by purchasing a metering device with a flow switch, adding a flow switch to the
facility, or using the same or shorter timer setting than the filter pump.
o Chlorine and acid pumps can be turned off manually. This can be done by using the
on/off button at the bottom of the dosing pump or via the manual control of the app.
Tot hier nagelezen
• The electronics or the device itself should never be connected to an output of a frequency
converter or frequency converter.
• If a frequency converter is used, we recommend placing it at least 3 m away from the dosing
unit, using a separate electrical circuit for the inverter and the salt electrolysis unit, and
checking the interactions between the frequency converter and the pH-RX measurement (check
that the pH and RX do not deviate when the inverter is switched on and off).
• All external power supplies and adapters for pool equipment must be connected to a power
source with 30 mA residual current protection.
• Make sure all equipment and pool water are properly grounded. The pool hose is grounded via
an in-line grounding to an independent grounding pole. • Before conducting any maintenance or
operation, ensure the salt chlorinator is unplugged, all machinery is turned off, and the power
source is switched off. Simple operation: the unit is very convenient to operate.
• NEVER make any adjustments inside the dispensing equipment.
• Our devices do not have an audible alarm, only an on-screen alarm.
Chemical
n the event of a leak, make sure water or chemicals cannot drip onto the installation
• Calibrate pH and prescription probes before first use and at least every 3 months thereafter.
Check the chlorine level and pH "regularly" with a staining method.
• The addition of pool chemicals should be done downstream of the pool accessories such as
the water heater, UV lamp, filter and downstream of the measuring probes
• Chlorine and acid react together to form toxic chlorine gas. Make sure the chemicals are
placed outdoors or in a very well-ventilated area, in a drip tray, that they cannot come into
contact with each other, and that they are kept out of reach of children...
• Have 2 sumps underneath the equipment to collect leaks at peristaltic pumps and injection
nipples. Sump pans should be positioned so that chlorine and acid leaks cannot mix.
• Repair leaking pipes immediately. Do not operate equipment with leaky pipes.
• Make sure the machines you use are programmed so that acid and chlorine are never added at
the same time.
• The acid dispenser should not be used with hydrochloric acid (HCl).
[Type here]