The optionally availabel charcoal
outer filter can be used to reduce
certain chemical air contaminations.
The inner filter (A, Fig 6) can be
pulled out of the unit.
Fig 6
The inner filter can be blown out with
air (to be done outside of building
only!), or can be washed out.
8. Trouble shooting
Unit doesn't start
*No electricity-
check mains and fuse.
*Defective switch, motor or cord-
consult an electrician.
*Overload fuse has reacted-
Wait and reset overload fuse.
Remote control doesn't work
*Batteries are down-
replace AAA Batteries.
*Infrared light transmission blocked-
visual contact must be given.
*Defective remote control or sensor-
consult an electrician.
Air flow too weak
*Clogged outer filter-
Replace filter.
*Clogged inner filter-
Blow out with air or wash filter.
9. Available accessories
Stock number 708731
Electrostatic outer filter (5 Micron,
replacement filter)
Stock number 708733
Inner filter (1 Micron, washable).
Stock number 708734
Charcoal outer filter (replacement
filter, reduces certain chemical air
contaminations).