Herunterladen Inhalt Inhalt Diese Seite drucken
Vorschau ausblenden Andere Handbücher für AFS-500:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB - ENGLISH
Operating Instructions
Dear Customer,
Many thanks for the confidence you have shown in us with the purchase of your new JET-product. This manual has been
prepared for the owner and operators of a JET AFS-500 air filtration system to promote safety during installation, operation and
maintenance procedures. Please read and understand the information contained in these operating instructions and the
accompanying documents. To obtain maximum life and efficiency from your air cleaner, and to use it safely, read this manual
thoroughly and follow instructions carefully.
...Table of Contents
1. Declaration of conformity
2. Warranty
3. Safety
Authorized use
General safety notes
1. Declaration of conformity
On our own responsibility we hereby
declare that this product complies with
the regulations* listed on page 2.
Designed in consideration with the
standards**.
2. Warranty
The Seller guarantees that the
supplied product is free from material
defects and manufacturing faults. This
warranty does not cover any defects
which are caused, either directly or
indirectly, by incorrect use,
carelessness, accidental damage,
repair, inadequate maintenance or
cleaning and normal wear and tear.
Guarantee and/or warranty claims
must be made within twelve months
from the date of purchase (date of
invoice). Any further claims shall be
excluded.
This warranty includes all guarantee
obligations of the Seller and replaces
all previous declarations and
agreements concerning warranties.
The warranty period is valid for eight
hours of daily use. If this is exceeded,
the warranty period shall be reduced
in proportion to the excess use, but to
no less than three months.
Returning rejected goods requires the
prior express consent of the Seller and
is at the Buyer's risk and expense.
Further warranty details can be found
in the General Terms and Conditions
(GTC). The GTC can be viewed at
www.jettools.com or can be sent by
post upon request.
The Seller reserves the right to make
changes to the product and
accessories at any time.
3. Safety
3.1 Authorized use
This air cleaner is designed for the
filtration of air borne wood dust only.
Any other application is not permitted
and may be carried out in specific
cases only after consulting with the
manufacturer.
.
The product is not suitable for use in
wet or humid environment.
Don't use appliance in places with a
risk of explosion.
Don't use appliance at temperatures
below 0°C.
The proper use also includes
compliance with the operating and
maintenance instructions given in this
manual.
The air cleaner must be operated only
by persons familiar with its operation
and maintenance and who are familiar
with its hazards.
The required minimum age must be
observed.
3
The air cleaner must only be used in a
technically perfect condition.
Before connecting the air cleaner to
electric power, all safety mechanisms
and covers must be mounted.
In addition to the safety requirements
contained in these operating
instructions and your country's
applicable regulations, you should
observe the generally recognized
technical rules concerning the dust
collection on woodworking machines.
Any other use exceeds authorization.
In the event of unauthorized use of the
product, the manufacturer renounces
all liability and the responsibility is
transferred exclusively to the operator.
3.2 General safety notes
Read and understand the entire
instruction manual before attempting
assembly or operation of the air
cleaner.
Keep this operating instruction close
by the product, protected from dirt and
humidity, and pass it over to the new
owner if you part with the tool.
No changes to the air cleaner may be
made.
Daily inspect the function and
existence of the safety appliances
before you start the air cleaner.
Do not attempt operation in this case,
protect the air cleaner by unplugging
the power cord.
Always disconnect the air cleaner
from the power source (unplug) before
servicing or changing filters.
Never reach into the machine while it
is operating or running down.
Replace contaminated filters.
Clogged filters will reduce the amount
of air circulation.
During the changing or cleaning of the
filters it's necessary to use a mask
(mask with filtration).

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Jet AFS-500

  • Seite 1: Inhaltsverzeichnis

    Dear Customer, Many thanks for the confidence you have shown in us with the purchase of your new JET-product. This manual has been prepared for the owner and operators of a JET AFS-500 air filtration system to promote safety during installation, operation and maintenance procedures.
  • Seite 2: Remaining Hazards

    The machine is designed to operate in closed rooms and can be placed on a 4. Machine specifications stable and levelled surface. 4.1 Technical data Make sure that the power cord does not impede work and cause people to Air volume flow 6, 8, 10 m³/min trip.
  • Seite 3: Changing Filters

    Inspect the proper function of the air Air flow too weak filtration system daily. *Clogged outer filter- Blow out with air or replace. Replace clogged filters. *Clogged inner filter- Clean the unit regularly. Blow out with air or replace. Defective safety devices must be replaced immediately.
  • Seite 4: Bestimmungsgemäße Verwendung

    Gebrauchsanleitung Sehr geehrter Kunde, vielen Dank für das Vertrauen, welches Sie uns beim Kauf Ihres neuen JET-Produktes entgegengebracht haben. Diese Anleitung ist für den Inhaber und die Bediener zum Zweck einer sicheren Inbetriebnahme, Bedienung und Wartung des Luftfiltersystems AFS-500 erstellt worden. Beachten Sie bitte die Informationen dieser Gebrauchsanleitung und der beiliegenden Dokumente.
  • Seite 5: Restrisiken

    Bewahren Sie die Benützen Sie das Elektrogerät nicht in Bedienungsanleitung, geschützt vor der Nähe von brennbaren Netzanschluss 230V ~1/N/PE 50Hz Schmutz und Feuchtigkeit, in der Flüssigkeiten oder Gasen. Abgabeleistung 0,12 kW ( 0,16PS) S1 Nähe des Gerätes auf, und geben Sie Beachten Sie die Brandmelde- und Betriebsstrom 0.3 A...
  • Seite 6: Elektrischer Anschluss

    Allgemeine Hinweise: Vor Wartungs- Reinigungs- und Der innere Filter (C, Fig4) ann aus Reparaturarbeiten muss das dem Gehäuse herausgezogen werden. Luftfiltersystem gegen Der innere Filter kann mit Luft Inbetriebnahme gesichert werden. ausgeblasen werden (nur im Freien Netzstecker ziehen! vornehmen!) Prüfen Sie täglich die ausreichende Funktion des Luftfiltersystems.
  • Seite 7: Utilisation Conforme

    Nous vous remercions de votre confiance que vous nous portez avec l’achat de votre nouvelle machine JET. Ce manuel a été préparé pour l’opérateur du système de filtration d’air JET AFS-500. Son but, mis à part le fonctionnement du système, est de contribuer à...
  • Seite 8 à 5.1 Montage protection et le fonctionnement l‘appareil. Avertir JET immédiatement si vous impeccable. constatez en déballant des pièces Tous travaux de branchement et de En cas de défauts à la machine ou endommagées par le transport et ne...
  • Seite 9: Changement De Filtre

    Le système de filtration d’air est Vérifier chaque jour le fonctionnement Purger le filtre intérieur avec un construit pour une utilisation dans un impeccable du système de filtration pistolet à air (seulement dehors en local fermé et fonctionne en position d’air.

Inhaltsverzeichnis