PROBLEM
Dehumidifier doesn't start
Does not dehumidify
High noise level
Ice formation on cooling coils
No water enters reservoir
Does not turn off when
water reservoir is full
If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidifier
TROUBLE CODE E1
When it shows E1,it is temperature sensor trouble or the connection wire not fixed
Change the temperature sensor or check the connection wire is loose or not, and refix it.
TROUBLE CODE E2
When it shows E2, it is humidity sensor trouble or the connection wire not fixed
Change the humidity sensor or check the connection wire is loose or not, and refix it.
TROUBLE CODE E4
When it shows E4,it is water pump trouble. Change or repair
This marking indicates that this product should not be disposed with other household wastes through-
out the EU. To prevent possible harm to the environment or human health from uncontrolled waste
disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your
us device, please use the return and collection systems or contact the retailer where the product was
purchased. They can take this product for environmental safe recycling.
TROUBLE SHOOTING
SOLUTION
- Check that the unit is connected to electricity and that fuse has not gone
- If the warning light is on, check that the water reservoir is empty and correctly placed in the
dehumidifier.
- Check that float is free
- Check that fan is spinning
- Check that air can flow freely through the dehumidifier. Front grid and air filter should be
clean and dehumidifier should stand 20-30 cm from wall
- Listen for sound of compression, but bear in mind that the dehumidifier may be in a dehu
midifying cycle, when the compression stops. Wait initially for about 35 minutes.
- Check that a thick coating of ice has not formed on the cooling coils
- Increase distance between dehumidifier and surrounding surfaces
- Remove air filter at rear of dehumidifier and check that no dust or fluff is obstructing
passage of air through machine
- Timer which controls defrosting may be broken, in which case compression
will not stop regularly
- Check for obstruction to drip-tray above water reservoir
- It is important that the float moves freely in the water reservoir. If it does not,
it will not respond to water levels and prevent dehumidifier from stopping