Control options
UNIT STATUS
The unit status can be selected from the Aidoo device, enabling on/off control of both the room
thermostat and the circuits, as well as domestic hot water (DHW).
OPERATION MODES
The modes that can be selected from the device are: Cooling mode, Heating mode and Auto
mode.
If the unit is operating in Auto mode, its operation will depend on the outdoor temperature and
the thermostat room temperature.
DHW CONTROL
The manufacturer's units allow you to manage domestic hot water (DHW) production status
control. The "Powerful" function can be activated in DHW production status control, which
forces the DHW to reach a temperature that has been preset in the configuration of the unit. If
DHW is turned off, it will not be possible to activate this parameter.
WORKING SETTINGS
The manufacturer's units can operate in both room temperature mode and in water supply
temperature mode.
The Aidoo device will be able to regulate the temperature in one or two circuits in water supply
temperature mode, while it can only regulate one circuit in room temperature mode.
SET-POINT TEMPERATURE
The unit temperature will depend on the working settings:
•
In room temperature mode, the thermostat room temperature will be selected, and in
supply temperature mode, the water supply temperature at which the unit is to operate will
be selected.
•
The DHW temperature can be selected within the ranges set by the unit's own main
thermostat.
The temperature limits can be obtained via protocol for room temperature mode, supply
temperature mode and DHW control, and they depend on the unit model.
EN
11