12 STORAGE
Thoroughly clean the whole machine and its accessories.
Protect it from exposure to direct sunlight. Keep it in the dark, if possible.
Don't keep it in plastic bags to avoid humidity build-up.
Pull the mains plug out of the socket and ventilate the appliance and all connected
pneumatic tools.Switch off the compressor and make sure that it is secured in such a way
that it cannot be started up again by any unauthorized person.
Store the compressor only in a dry location which is not accessible to unauthorized
persons.Always store upright, never tilted!
13 TROUBLE SHOOTING
PROBLEM
Leakage of air from the
valve of the pressure
switch with the
compressor off.
Reduction of
performance. Frequent
start-up. Low pressure
values.
The compressor stops
and restarts automatically
after a few minutes.
After a few attempts to
restart, the compressor
stops.
The compressor does not
stop and the safety valve
is tripped.
Any other type of operation must be carried out by authorized Service Centers, requesting
original parts. Tampering with the machine may impair its safety and in any case make the
warranty null and void.
Copyright © 2021 VARO
POWX1750
CAUSE
Check valve that, due to
wear or dirt on the seal,
does not perform its
function correctly.
Excessive performance
request, check for any
leaks from the couplings
and/or pipes. Intake filter
may be clogged.
Tripping of the thermal
cutout due to overheating
of the motor.
Tripping of the thermal
cutout due to overheating
of the motor (removal of
the plug with the
compressor running, low
power voltage).
Irregular functioning of the
compressor or breakage
of the pressure switch.
P a g e
| 9
SOLUTION
Unscrew the hexagonal
head of the check valve,
clean the valve seal and
the special rubber disk
(replace if worn).
Reassemble and tighten
carefully.
Replace the seals of the
fitting, clean or replace
the filter.
Clean the air ducts.
Ventilate the work area.
Activate the on/off switch.
Ventilate the work area.
Wait a few minutes. The
compressor will restart
independently.
Remove the plug and
contact the Service
Center.
www.varo.com