Specifications
Range
pH
Resolution
Accuracy
Calibration
Buffers
Temperature Compensation
ISO-pH
Slope
Range
mV
Resolution
Accuracy
Calibration
Range
DISS. OXYGEN
Resolution
Accuracy
Calibration
Temperature Compensation
Range
TEMPERATURE
Resolution
Accuracy
Calibration
pH/mV/Dissolved Oxygen
CHANNELS
Temperature
INPUTS
Reminder
CALIBRATION
GLP
On/Off
CONTROL
Proportional
Set-up/Calibration
DISPLAY
Real Time Clock
Languages
Built-in
RECORDER
Interval
Two Outputs
Baud Rate
RS485
Computer
Values (computer)
DATA-LOGGING
Interval
RELAY OUTPUTS
Relays
Mains
Identification Number
SECURITY
Password Protection
POWER SUPPLY
Mains
DIMENSIONS
WxDxH
WEIGHT
Meter
R305
0...14 pH
0.01 pH
0.1% ± 1 digit
1...2 points
9 + 2 user specified
-30...+130°C
6...8 pH
80...120%
±2000 mV
1 mV
0.1% ± 1 digit
1 point
0...60 mg/l (0...600%)
0.05 mg/l (0.5%)
1% ± 1 digit
1 point
0...50°C
-30...+130°C
0.1°C
0.3°C
±10°C
2
2 for Pt1000 (or Pt100)
screw terminals
0...999 h
ü
ü
ü
128x64 pixels
ü
EN, NL, FR, DE
1200 points
1...9999 s
4...20 mA, max. 300 Ω load
300...9600 b/s
via RS485/RS232 interface
1200 + °C/date/time
1...9999 s
4 solid state
12...250 VAC/ max. 0.5 A
ü
ü
210...250 VAC
20x9x12 cm
1.2 kg
Specifications
Range
CONDUCTIVITY
Resolution
Accuracy
Calibration
Standards
Cell Constant
Temperature Compensation
Reference Temperature
Temperature Coefficient
Capacitive Compensation
Range
RESISTIVITY
Resolution
Range
TDS
Resolution
Range
TEMPERATURE
Resolution
Accuracy
Calibration
CHANNELS
pH/mV/Dissolved Oxygen
Temperature
INPUTS
Reminder
CALIBRATION
GLP
On/Off
CONTROL
Proportional
Set-up/Calibration
DISPLAY
Real Time Clock
Languages
Built-in
RECORDER
Interval
Two Outputs
RS485
Baud Rate
Computer
Values (computer)
DATA-LOGGING
Interval
Relays
RELAY OUTPUTS
Mains
Identification Number
SECURITY
Password Protection
POWER SUPPLY
Mains
DIMENSIONS
WxDxH
WEIGHT
Meter
R315
0...2000 mS/cm
0.01 µS/cm
0.5% f.s. of range
1 point
0.01/0.1/1 M KCl
-1
0.1/1/10 cm
± 50%
-30...+130°C
20° or 25°C
natural waters (EN27888)
ü
0...20 MΩ.cm
1 Ω.cm
0...100 g/l
0.01 mg/l
-30...+130°C
0.1°C
0.3°C
±10°C
2
2 for Pt1000 (or Pt100)
screw terminals
0...999 h
ü
ü
ü
128x64 pixels
ü
EN, NL, FR, DE
1200 points
1...9999 s
4...20 mA, max. 300 Ω load
300...9600 b/s
via RS485/RS232 interface
1200 + °C/date/time
1...9999 s
3 solid state
12...250 VAC/ max. 0.5 A
ü
ü
210...250 VAC
20x9x12 cm
1.2 kg