Herunterladen Inhalt Inhalt Diese Seite drucken
Verfügbare Sprachen

Verfügbare Sprachen

DP3B
UTL1482Z
DP3H
UTL1604Z
DP3Y
UTL1632Z
DP3B-BSP
UTL1482ZB
DP3H-BSP
UTL1604ZB
DP3Y-BSP
UTL1632ZB
SYMBOL DEFINITION
Do not pump flammable materials. Fire could occur.
Do not pump hazardous material.
Read your product literature before use.
Do not smoke or bring flame near gasoline.
Disconnect spark plug before performing
maintenance, adjustment, lubrication, and
storage.
SAFETY PRECAUTIONS
• This pump is designed for pumping only water. Under no circumstances
should it be used for pumping hazardous materials including
flammable materials such as gasoline.
• Before start-up, study all of the instructions in this manual. Be sure
you thoroughly understand how to operate the pump. Proper
preparation, operation and simple maintenance will improve operator
safety, pump performance and long unit life.
• Be sure that each person who operates the machine is properly
instructed as to its safe operation.
Part No. L19948 Rev. F 2009/11/18
SELF-PRIMING DIAPHRAGM PUMP
MODEL / UT NUMBER / DESCRIPTION:
3-INCH DIAPHRAGM PUMP, BRIGGS & STRATTON ENGINE
3-INCH DIAPHRAGM PUMP, HONDA GX160 ENGINE
3-INCH DIAPHRAGM PUMP, YANMAR DIESEL ENGINE
3-INCH DIAPHRAGM PUMP, BRIGGS & STRATTON ENGINE, BSP NIPPLE CONNECTIONS
3-INCH DIAPHRAGM PUMP, HONDA GX160 ENGINE, BSP NIPPLE CONNECTIONS
3-INCH DIAPHRAGM PUMP, YANMAR DIESEL ENGINE, BSP NIPPLE CONNECTIONS
INSTRUCTIONS & PARTS LIST
• Always keep the machine and associated equipment clean, properly
serviced and maintained according to the instructions in this manual.
• Observe all safety regulations for the safe handling and storage of
fuel. Handle fuel in approved vented fuel cans. Do not store fuel
supplies in a garage, shed or other areas attached to living quarters.
Do not refill the fuel tank in an area attached to living quarters. Do not
refill the engine while it is running or hot. Carefully clean up any
spilled fuel before starting the engine.
• Do not smoke or bring flame near gasoline.
• Do not operate the pump at shut-off pressure.
• Do not operate this pump if any safety equipment or guard has been
removed.
• Never operate the machine in any explosive atmosphere, near
combustible materials, or where there is not enough ventilation to
carry off the exhaust fumes. DO NOT operate pump indoors or in crawl
spaces.
• Always be sure the machine is on secure footing and cannot shift to
where it might injure someone. Remember that the suction hose on
the pump tends to pull the pump towards the liquid source during
pumping.
• Keep the immediate area free of bystanders.
• When pulling the starter, be sure that nothing is in a position to be hit
by the operator's hand or arm, or the starting rope.
• Do not touch the hot cylinder and muffler area.
• Shut off the engine and disconnect the spark plug wire before working
on any part of the machine.
• Long or continuous exposure to high noise levels, such as the
operation of a gasoline engine, may cause permanent hearing
impairment or other possible effects. Hearing protection devices are
available from your dealer, or can be ordered through him.
• Use only genuine product manufacturer's replacement parts. Failure
to do so may cause poor fit and possible injury.
• BEWARE OF USING THIS EQUIPMENT IN CONFINED SPACES.
BEWARE OF USING THIS EQUIPMENT IN CONFINED SPACES.
BEWARE OF USING THIS EQUIPMENT IN CONFINED SPACES.
BEWARE OF USING THIS EQUIPMENT IN CONFINED SPACES.
BEWARE OF USING THIS EQUIPMENT IN CONFINED SPACES.
Confined spaces, without sufficient fresh air ventilation, can contain
dangerous gases. Running gasoline engines in such environments
can lead to deadly explosions and/or asphyxiation.
Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Riverside DP3B

  • Seite 7: Anleitung Und Teileliste

    MEMBRANPUMPE MODELL / UT NUMMER / BESCHREIBUNG: DP3B UTL1482Z 3" MEMBRANPUMPE, BRIGGS & STRATTON 3½HP MOTOR DP3H UTL1604Z 3" MEMBRANPUMPE, HONDA 5½HP MOTOR DP3Y UTL1632Z 3" MEMBRANPUMPE, YANMAR 4.7HP DIESEL MOTOR DP3B-BSP UTL1482ZB 3" MEMBRANPUMPE, BRIGGS & STRATTON 3½HP MOTOR, SCHLAUCHANSCHLÜSSE - BSP...
  • Seite 8: Auspacken Der Pumpe

    AUSPACKEN DER PUMPE BETRIEBSANLEITUNG Achten Sie sorgfältig auf Versandschäden. Wenn Sie irgendeinen 1. Verwenden Sie ein Sieb am Ende der Saugleitung. Schaden bemerken, benachrichtigen Sie Ihren Händler oder den 2. Stellen Sie sicher, dass alle Schlauch- und Rohranschlüsse luftdicht Spediteur. Entfernen Sie alle Versandblöcke und Klammern. Wenn das sind.
  • Seite 11: Garantia Limitada

    El servicio derivado de la garantía puede ser obtenido en cualquier distribuidor Riverside Pump Manufacturing Inc. autorizado para efectuar las reparaciones que resulten necesarias. En caso de que usted necesite alguna operación de servicio derivada de la garantía, verifique primero cuál es el distribuidor de Riverside Pump Manufacturing Inc.

Diese Anleitung auch für:

Dp3hDp3yDp3b-bspDp3h-bspDp3y-bsp

Inhaltsverzeichnis