USEFUL APPLICATIONS
RUN NOTEBOOK COMPUTERS, RADIOS, TVS, VCRS,
LAMPS, FANS, FAX, DRILL, . . . . . . ETC.
SPECIFICATION
INPUT VOLTAGE RANGE : DC 10~15V (12V)
STANDBY INPUT CURRENT : <0.5A (12V)
OUTPUT VOLTAGE (AC) : 230V
OUTPUT WAVEFORM : MODIFY SINEWAVE
OUTPUT FREQUENCY : 50Hz
CONTINUE OUTPUT POWER : 600W
PEAK OUTPUT POWER : 1500W
EFFICIENCY : 85~90%
BATTERY LOW PRE-ALARM : 10.5 ± 0.5V (12V)
BATTERY LOW SHUTDOWN : 10 ± 0.5V (12V)
THERMAL PROTECT : 60 ± 5°C (MICROCONTROLLER )
OVERLOAD PROTECT : YES (MICROCONTROLLER )
OUTPUT SHORT PROTECT : YES ( MICROCONTROLLER )
BATTERY EX. 12V / 24V PROTECT : YES ( MICROCONTROLLER )
BATTERY POLARITY PROTECT : YES (BY FUSE )
FUSE : 25A*3PCS (12V)
DIMENSION ( L *W*H) mm : 200*173*65
WEIGHT : 2000g
TROUBLESHOOTING
IF THE INVERTER DOES NOT APPEAR TO BE FUNCTIONING
PROPERLY, THERE ARE SEVERAL REASONS WHY THE
INVERTER MAY NOT BE RESPONDING.
1) POOR CONTACT
*CLEAN CONTACT PARTS THOROUGHLY
1
EN
2) RECEPTACLE HAS NO POWER
*CHECK CAR FUSE, REPLACE DAMAGED FUSE
*CHECK RECEPTACLE WIRING. REPAIR IF NECESSARY
3) FUSE IS BLOWN
*THE FUSE IS LOCATED INSIDE THE P.C.B. REPLACE FUSE
WITH A FUSE OF EQUIVALENT VALUE
4) OVERLOAD CAUSED AC OUTPUT REDUCE
*REDUCE THE WATTAGE OF YOUR LOAD TO LOWER THAN
600 WATTS
5) THERMAL CAUSED AC OUTPUT REDUCE
*UNDER HEAVY LOADS FOR EXTENDED PERIODS OF
TIME. THE AC INVERTER WILL REDUCE OUTPUT TO
PREVENT DAMAGE TO EXCESS HEAT. IF THIS HAPPENS,
PLEASE PROCEED AS BELOW :
(A) SWITCH OFF THE POWER SWITCH OF THIS INVERTER
(B) DECREASE LOAD OF THIS MACHINE I. E.
DISCONNECT SOME OF THE APPLIANCES OR WAIT
UNTIL THIS INVERTER BECOME COOL.
(C) SWITCH ON THE POWER SWITCH OF THIS INVERTER.
6) LOW-BATTERY SHUTDOWN
*RECHARGE YOUR BATTERY AND RESUME OPERATION.
CAUTION
ALWAYS PLACE THE INVERTER IN AN
ENVIRONMENT WHICH IS:
(A) WELL VENTILATED
(B) NOT EXPOSED TO DIRECT SUNLIGHT
OR HEAT SOURCE
(C) OUT OF REACH FROM CHILDREN
(D) AWAY FROM WATER/MOISTURE, OIL OR GREASE
(E) AWAY FROM ANY FLAMMABLE SUBSTANCE
EN