ADJUSTING THE TEMPERATURE
To change the set temperature [F/C], the device must be in a temperature-controlled
operating mode. Use the navigation buttons to increase (+) or decrease (-) the
temperature [F/C]. Holding down one of the buttons will increase the adjustment speed.
CHANGING THE TEMPERATURE UNIT [F <-> C]
To change the unit of the displayed temperature (F= Fahrenheit, C= Celsius), the device
must be in a temperature-controlled operating mode. Then, press and hold the (-) button
until the lower limit of the temperature is reached in any temperature unit. Pressing or
continuing to hold the (-) button afterward will automatically switch the displayed
temperature to the upper limit of the other temperature unit. By holding the (+) button
beyond the upper limit [F], the temperature control will be completely deactivated (OFF).
PUFF-TIME LIMIT
If the fire button is pressed for more than 10 seconds, the device will automatically
interrupt the power output to prevent overheating or dry firing of the atomizer.
REVERSE POLARITY PROTECTION
Always ensure the correct orientation of the battery when inserting it into the battery
compartment. If a battery is inserted with the wrong orientation, the integrated reverse
polarity protection prevents damage to the electronics. The device cannot be turned on or
charged in this state.
BATTERY CHARGING
The PIPELINE BOX is equipped with a separate PCB, that allows the charging of an
inserted Li-ION battery through the USB-C port. Use only a high-quality and adequately
24 English
dimensioned charging cable/power adapter for this purpose (not included).
We recommend using specialized external chargers for charging Li-ION batteries.
Especially for small cell types (e.g., 18500, 18350), their lifespan can be significantly
increased by using an appropriately lower charging current (≤0.5 C).
E R R O R M E S S A G E S
CHECK ATOMIZER
The device is unable to detect the resistance [Ω] of the attached atomizer/coil.
Please check for dirt or debris on the contact points between the atomizer and the device
and clean them if necessary. Ensure that the atomizer is screwed on flush and that the
positive pole of the atomizer makes contact with the device (adjust if necessary).
Inspect the coil of the atomizer (consider replacing if necessary).
SHORTED
The device detects a short circuit in the attached atomizer.
Please check the isolators of the atomizer. Inspect the coil of the atomizer (consider
replacing if necessary).
WEAK BATTERY
The resting voltage of the inserted battery is below 3.2 volts.
Insert a charged battery or connect an appropriate charging cable/power supply to the
USB-C port of the device.
An unusual frequency of this error message often indicates a reduced battery capacity
due to improper storage, handling, or intensive use (consider replacing if necessary).