Herunterladen Diese Seite drucken

HANSGROHE Metris 31480009 Gebrauchsanleitung, Montageanleitung Seite 2

Vorschau ausblenden Andere Handbücher für Metris 31480009:

Werbung

Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
• The product is exclusively designed for drinking
water!
• Safety against backflow
Symbol description
Do not use silicone containing acetic acid!
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work
2
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
max. 70°C / 4 min
Cause
- check valve hasn't moved back
- Shower filter seal dirty
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
- Shower filter seal dirty
- check valve hasn't moved back
- Flow limiter in handshower isn't re-
moved
Assembly (see page 4)
English
Adjustment (see page 6)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Dimensions (see page 7)
Flow diagram (see page 7)
Spare parts (see page 10)
Cleaning (see page 9)
Operation (see page 12)
Maintenance (see page 8)
The check valves must be checked regularly according
to DIN EN 1717 in accordance with national or
regional regulations (at least once a year).
65°C
Remedy
- Exchange check valves
- Clean filter seal between shower
and hose
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Clean filter seal between shower
and hose
- Exchange check valves
- Remove flow limiter

Werbung